Application of iDose in low-dose CT cardiac imaging in patients with congenital heart disease
Jun Jiang, Changhong Liang, Yang Lin, Jinglei Li, Qishun Liu
Abstract
Jun Jiang, Changhong Liang, Yang Lin, Jinglei Li, Qishun Liu
Abstract
Objective To evaluate the value of iterative reconstruction (iDose) in low-dose CT cardiac imaging in patients with congenital heart disease (CHD).Methods Eighty-eight consecutive CHD patients referred for preoperative or post-operative CT were randomly diveded into 4 groups and undergone a prospective ECG-gated MDCT angiography with protocol A (routine low-dose depending on patient weight),B (30% of A),C (50%),and D (70% D),respectively.Filtered back projection (FBP) and grades 2,4,6 of iDose were used for all reconstruction.Noises were measured at the root of ascending aorta and main pulmonary artery.Image qualities were graded (scale from one to five) and compared among 4 groups.Results The lowest image noise was measured in images reconstructed with grade 6 of iDose (P < 0.05)while the highest one was measured in that with FBP in all groups.The subjective scores in Group D with iDose 6 reconstruction were no less than 3.The subjective score in Group D with iDose 6 was similar to that in Group A with FBP.Effective radiation dose in group D was (0.65 ± 0.43) mSv.Conclusion Using iDose technique would reduce noise and improve image quality effectively.Grade 6 of iDose might be the best choice and would reduce effective dose by 70% in MDCT angiography in CHD patients. Key words: Congenital heart disease; Tomography, X-ray computed; Iterative reconstruction; Low-dose
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective To evaluate the value of iterative reconstruction (iDose) in low-dose CT cardiac imaging in patients with congenital heart disease (CHD).Methods Eighty-eight consecutive CHD patients referred for preoperative or post-operative CT were randomly diveded into 4 groups and undergone a prospective ECG-gated MDCT angiography with protocol A (routine low-dose depending on patient weight),B (30% of A),C (50%),and D (70% D),respectively.Filtered back projection (FBP) and grades 2,4,6 of iDose were used for all reconstruction.Noises were measured at the root of ascending aorta and main pulmonary artery.Image qualities were graded (scale from one to five) and compared among 4 groups.Results The lowest image noise was measured in images reconstructed with grade 6 of iDose (P < 0.05)while the highest one was measured in that with FBP in all groups.The subjective scores in Group D with iDose 6 reconstruction were no less than 3.The subjective score in Group D with iDose 6 was similar to that in Group A with FBP.Effective radiation dose in group D was (0.65 ± 0.43) mSv.Conclusion Using iDose technique would reduce noise and improve image quality effectively.Grade 6 of iDose might be the best choice and would reduce effective dose by 70% in MDCT angiography in CHD patients. Key words: Congenital heart disease; Tomography, X-ray computed; Iterative reconstruction; Low-dose
Key concepts: Medicine, Nuclear medicine, Radiology, Effective dose (radiation), Heart disease, Coronary artery disease, Angiography, Image noise