The influence of different autoclaving steralization parameters on the performance of dental handpieces
Pingying Xu, Luo Dan, Jiang Chandi, Weibin Peng
Abstract
Pingying Xu, Luo Dan, Jiang Chandi, Weibin Peng
Abstract
Objective To discuss the influence of different autoclaving on performance of dental handpieces to provide evidence for the clinical choices of proper dental instrument sterilization procedures. Methods Orthogonal experiment method was adopted.45 totally new high-speed dental handpieces were randomly divided into 9 groups according to the three factors of autoclaving, including sterilizing temperature (132 ℃, 134 ℃ , 136 ℃), sterilizing duration(4 min, 5 min, 6 min, ) and desccination time (10 min, 15 min, 20 min) by the method of three factors-levels.All these high-speed dental handpieces were sterilized, and number of maintenance in 8 months was recorded and the three factors was analyzed. Results Each handpiece experienced 1 060 times of autoclaving in 8 months.Variable A (sterilizing temperature) P 0.05. Conclusion Autoclaving temperature and duration time had impact on the performances of dental handpieces.Desiccation time showed less obvious effect on performances of handpieces. Key words: Dental handpieces; High-pressure steam sterilization; Temperature; Time; Usability
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective To discuss the influence of different autoclaving on performance of dental handpieces to provide evidence for the clinical choices of proper dental instrument sterilization procedures. Methods Orthogonal experiment method was adopted.45 totally new high-speed dental handpieces were randomly divided into 9 groups according to the three factors of autoclaving, including sterilizing temperature (132 ℃, 134 ℃ , 136 ℃), sterilizing duration(4 min, 5 min, 6 min, ) and desccination time (10 min, 15 min, 20 min) by the method of three factors-levels.All these high-speed dental handpieces were sterilized, and number of maintenance in 8 months was recorded and the three factors was analyzed. Results Each handpiece experienced 1 060 times of autoclaving in 8 months.Variable A (sterilizing temperature) P 0.05. Conclusion Autoclaving temperature and duration time had impact on the performances of dental handpieces.Desiccation time showed less obvious effect on performances of handpieces. Key words: Dental handpieces; High-pressure steam sterilization; Temperature; Time; Usability
Key concepts: Sterilization (economics), Dental instruments, Dentistry, Medicine, Foreign exchange, Economics, Monetary economics, Foreign exchange market