2009Chin J EndemiolRequires access

Method for the determination of broad concentration range of iodide in drinking water by spectrophotometry with alkaline potassium permanganate oxidation

Yaping Zhang, Yanhong Huang, Liqing Lin

Open publisher page 0 citations

Abstract

Objective To establish a simple photometric method for the determination of broad concentration range of iodide in drinking water. Methods Iodide in water was oxidized with potassium permanganate in alkaline medium to generate iodate. After excessive oxidant was eliminated with nitrite sodium in acidic medium condition and excessive nitrite was eliminated with a mixture of aminosulfonic acid and urea, iodate was used to react with potassium iodide reagent to form I_2 which further reacted with amylum to form color complex. The absorbance was determined by photometry. In determination reagent system suitable amount of iodide that acted as background and sodium chloride were added to solve the problem of the chromogenic sensitivity, i.e., when iodine concentration was < 100 μg/L in water sample the degree of iodine-starch complex color change could not be in linear proportion to the concentration of iodine in water. Results The linear range of the calibration curve of the new method for iodine was 0-1200 μg/L and the linear correlative coefficient was 0.9998. The detection limit for iodine was 4 μg/L. Results of 6 times repeated determination of water samples with iodine concentration of 76.6, 207.8, 560.4 μg/L showed that the relative standard deviations(RSD) were all under 1%. The recovery of standard addition for iodine added in 8 water samples of different iodide concentration levels was 97.0% (485.2/500.0) - 102.5% (102.5/100.0). Interference of hexavalent chromium(Cr~(6+)) in water was eliminated when treated with ferrous reagent. Interference of bromate (BrO_3~-) in water was eliminated when treated with potassium bromide and nitrite sodium reagent. Zero point two mg/L Cr~(6+), 0.1 mg/L BrO_3~- in water were noninterference. Conclusion This method can be easily performed with good precision and accuracy and has broad detection concentration range, which is suitable for measuring iodide in drinking water. Key words: Iodides;  Water;  Spectrophotometry

About this research paper

What this paper is about

Objective To establish a simple photometric method for the determination of broad concentration range of iodide in drinking water. Methods Iodide in water was oxidized with potassium permanganate in alkaline medium to generate iodate. After excessive oxidant was eliminated with nitrite sodium in acidic medium condition and excessive nitrite was eliminated with a mixture of aminosulfonic acid and urea, iodate was used to react with potassium iodide reagent to form I_2 which further reacted with amylum to form color complex. The absorbance was determined by photometry. In determination reagent system suitable amount of iodide that acted as background and sodium chloride were added to solve the problem of the chromogenic sensitivity, i.e., when iodine concentration was < 100 μg/L in water sample the degree of iodine-starch complex color change could not be in linear proportion to the concentration of iodine in water. Results The linear range of the calibration curve of the new method for iodine was 0-1200 μg/L and the linear correlative coefficient was 0.9998. The detection limit for iodine was 4 μg/L. Results of 6 times repeated determination of water samples with iodine concentration of 76.6, 207.8, 560.4 μg/L showed that the relative standard deviations(RSD) were all under 1%. The recovery of standard addition for iodine added in 8 water samples of different iodide concentration levels was 97.0% (485.2/500.0) - 102.5% (102.5/100.0). Interference of hexavalent chromium(Cr~(6+)) in water was eliminated when treated with ferrous reagent. Interference of bromate (BrO_3~-) in water was eliminated when treated with potassium bromide and nitrite sodium reagent. Zero point two mg/L Cr~(6+), 0.1 mg/L BrO_3~- in water were noninterference. Conclusion This method can be easily performed with good precision and accuracy and has broad detection concentration range, which is suitable for measuring iodide in drinking water. Key words: Iodides;  Water;  Spectrophotometry

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To establish a simple photometric method for the determination of broad concentration range of iodide in drinking water. Methods Iodide in water was oxidized with potassium permanganate in alkaline medium to generate iodate. After excessive oxidant was eliminated with nitrite sodium in acidic medium condition and excessive nitrite was eliminated with a mixture of aminosulfonic acid and urea, iodate was used to react with potassium iodide reagent to form I_2 which further reacted with amylum to form color complex. The absorbance was determined by photometry. In determination reagent system suitable amount of iodide that acted as background and sodium chloride were added to solve the problem of the chromogenic sensitivity, i.e., when iodine concentration was < 100 μg/L in water sample the degree of iodine-starch complex color change could not be in linear proportion to the concentration of iodine in water. Results The linear range of the calibration curve of the new method for iodine was 0-1200 μg/L and the linear correlative coefficient was 0.9998. The detection limit for iodine was 4 μg/L. Results of 6 times repeated determination of water samples with iodine concentration of 76.6, 207.8, 560.4 μg/L showed that the relative standard deviations(RSD) were all under 1%. The recovery of standard addition for iodine added in 8 water samples of different iodide concentration levels was 97.0% (485.2/500.0) - 102.5% (102.5/100.0). Interference of hexavalent chromium(Cr~(6+)) in water was eliminated when treated with ferrous reagent. Interference of bromate (BrO_3~-) in water was eliminated when treated with potassium bromide and nitrite sodium reagent. Zero point two mg/L Cr~(6+), 0.1 mg/L BrO_3~- in water were noninterference. Conclusion This method can be easily performed with good precision and accuracy and has broad detection concentration range, which is suitable for measuring iodide in drinking water. Key words: Iodides;  Water;  Spectrophotometry

Key concepts: Chemistry, Iodine, Iodate, Potassium permanganate, Iodide, Potassium iodate, Spectrophotometry, Absorbance

Related papers

Back to paper searchBrowse research topicsOriginal source
Method for the determination of broad concentration range of iodide in drinking water by spectrophotometry with alkaline potassium permanganate oxidation — Research Paper | ScholarLens