Comparison of different exposure modes with full-field digital mammography: image quality versus radiation dose

Yongxia Zhao, Guang-Lu Liang, Yingjin Xu, Xiao Tian, Xiaoping Yin

Open publisher page 0 citations

Abstract

Objective To study the difference of image quality and radiation dose between different exposure modes with full-field digital mammography (FFDM).Methods The Fluke18-220mammographic phantom was exposed by FFDM system with different exposure modes at automatic exposure control ( AEC ) ,including contrast mode,standard mode and dose mode,and the exposure factors and radiation dose were recorded.The images on monitor with the best window width and window level were read by four independent radiologists.The images of specks groups,nylon fibers and masses was assessed by the four experienced readers at the criterion of American College of Radiology.Results The detection of specks groups,nylon fibers and masses were statistically different at the contrast mode and standard mode (F =41.321,P < 0.05),further at the contrast mode and dose mode.The detection of specks groups、nylon fibers and masses were not statistically different( P > 0.05 ) at standard mode and dose mode,but the radiation doses were different.The ESD at standard mode and dose mode was 4.5 and 3.15 mGy,respectively.The AGD of standard mode and dose mode was 1.18 mGy and 0.78 mGy,respectively.Conclusions The standard mode and dose mode of FFDM might be fit for most patients,especially at the dose mode.Contrast mode of FFDM should be strictly controled in use. Key words: Full-field digital mammography;  Exposure mode;  Image quality;  Radiation dose

About this research paper

What this paper is about

Objective To study the difference of image quality and radiation dose between different exposure modes with full-field digital mammography (FFDM).Methods The Fluke18-220mammographic phantom was exposed by FFDM system with different exposure modes at automatic exposure control ( AEC ) ,including contrast mode,standard mode and dose mode,and the exposure factors and radiation dose were recorded.The images on monitor with the best window width and window level were read by four independent radiologists.The images of specks groups,nylon fibers and masses was assessed by the four experienced readers at the criterion of American College of Radiology.Results The detection of specks groups,nylon fibers and masses were statistically different at the contrast mode and standard mode (F =41.321,P < 0.05),further at the contrast mode and dose mode.The detection of specks groups、nylon fibers and masses were not statistically different( P > 0.05 ) at standard mode and dose mode,but the radiation doses were different.The ESD at standard mode and dose mode was 4.5 and 3.15 mGy,respectively.The AGD of standard mode and dose mode was 1.18 mGy and 0.78 mGy,respectively.Conclusions The standard mode and dose mode of FFDM might be fit for most patients,especially at the dose mode.Contrast mode of FFDM should be strictly controled in use. Key words: Full-field digital mammography;  Exposure mode;  Image quality;  Radiation dose

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To study the difference of image quality and radiation dose between different exposure modes with full-field digital mammography (FFDM).Methods The Fluke18-220mammographic phantom was exposed by FFDM system with different exposure modes at automatic exposure control ( AEC ) ,including contrast mode,standard mode and dose mode,and the exposure factors and radiation dose were recorded.The images on monitor with the best window width and window level were read by four independent radiologists.The images of specks groups,nylon fibers and masses was assessed by the four experienced readers at the criterion of American College of Radiology.Results The detection of specks groups,nylon fibers and masses were statistically different at the contrast mode and standard mode (F =41.321,P < 0.05),further at the contrast mode and dose mode.The detection of specks groups、nylon fibers and masses were not statistically different( P > 0.05 ) at standard mode and dose mode,but the radiation doses were different.The ESD at standard mode and dose mode was 4.5 and 3.15 mGy,respectively.The AGD of standard mode and dose mode was 1.18 mGy and 0.78 mGy,respectively.Conclusions The standard mode and dose mode of FFDM might be fit for most patients,especially at the dose mode.Contrast mode of FFDM should be strictly controled in use. Key words: Full-field digital mammography;  Exposure mode;  Image quality;  Radiation dose

Key concepts: Automatic exposure control, Digital mammography, Image quality, Nuclear medicine, Radiation dose, Mammography, Contrast (vision), Digital radiography

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison of different exposure modes with full-field digital mammography: image quality versus radiation dose — Research Paper | ScholarLens