2016•Zhonghua jizhen yixue zazhiRequires access

Effect of different positive end-expiratory pressure levels on stroke volume variations in patients with acute respiratory distress syndrome treated with mechanical ventilation

Tengxiao Xu, Jianzhong Yang, Peng Peng

Open publisher page 0 citations

Abstract

Objective To investigate the effect of different PEEP levels on stroke volume variation(SVV) in patients with acute respiratory distress syndrome(ARDS) treated with mechanical ventilation for predicting cardiac pre-load and the changes of hemodynamics. Methods Thirty critical patients with ARDS met the new criteria in 2012 set at European Berlin were enrolled in this study with measured values(MV) in EICU from September 2012 to October 2013.The changes in SVV and cardiac output(CO) monitored with Vigileo system were determined at different selected PEEE levels of 5, 7, 9, 11, 13, 15 mmHg.At the same time, MAP and CVP were measured. Results Variation of PEEP levels led to a significant changes in SVV, CO(P 0.05). The changes of CO showed a downtrend decline with the increase in PEEP levels.When PEEP was set at 13 mmHg and higher , the value of SVV denoted pre-load insufficiency. When PEEP was set at 11 mmHg or higher, cardiac output decreased.CVP could not predict the changes of pre-load. Conclusion Increase in PEEP levels can significantly reduce the cardiac pre-load.SVV can be a useful indicator of the changes in cardiac pre-load induced by high PEEP, suggesting fluid replacement necessary in time. Key words: Acute respiratory distress syndrome; Positive end-expiratory pressure; Stroke volume variations; Cardiac output; Central venous pressure

About this research paper

What this paper is about

Objective To investigate the effect of different PEEP levels on stroke volume variation(SVV) in patients with acute respiratory distress syndrome(ARDS) treated with mechanical ventilation for predicting cardiac pre-load and the changes of hemodynamics. Methods Thirty critical patients with ARDS met the new criteria in 2012 set at European Berlin were enrolled in this study with measured values(MV) in EICU from September 2012 to October 2013.The changes in SVV and cardiac output(CO) monitored with Vigileo system were determined at different selected PEEE levels of 5, 7, 9, 11, 13, 15 mmHg.At the same time, MAP and CVP were measured. Results Variation of PEEP levels led to a significant changes in SVV, CO(P 0.05). The changes of CO showed a downtrend decline with the increase in PEEP levels.When PEEP was set at 13 mmHg and higher , the value of SVV denoted pre-load insufficiency. When PEEP was set at 11 mmHg or higher, cardiac output decreased.CVP could not predict the changes of pre-load. Conclusion Increase in PEEP levels can significantly reduce the cardiac pre-load.SVV can be a useful indicator of the changes in cardiac pre-load induced by high PEEP, suggesting fluid replacement necessary in time. Key words: Acute respiratory distress syndrome; Positive end-expiratory pressure; Stroke volume variations; Cardiac output; Central venous pressure

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To investigate the effect of different PEEP levels on stroke volume variation(SVV) in patients with acute respiratory distress syndrome(ARDS) treated with mechanical ventilation for predicting cardiac pre-load and the changes of hemodynamics. Methods Thirty critical patients with ARDS met the new criteria in 2012 set at European Berlin were enrolled in this study with measured values(MV) in EICU from September 2012 to October 2013.The changes in SVV and cardiac output(CO) monitored with Vigileo system were determined at different selected PEEE levels of 5, 7, 9, 11, 13, 15 mmHg.At the same time, MAP and CVP were measured. Results Variation of PEEP levels led to a significant changes in SVV, CO(P 0.05). The changes of CO showed a downtrend decline with the increase in PEEP levels.When PEEP was set at 13 mmHg and higher , the value of SVV denoted pre-load insufficiency. When PEEP was set at 11 mmHg or higher, cardiac output decreased.CVP could not predict the changes of pre-load. Conclusion Increase in PEEP levels can significantly reduce the cardiac pre-load.SVV can be a useful indicator of the changes in cardiac pre-load induced by high PEEP, suggesting fluid replacement necessary in time. Key words: Acute respiratory distress syndrome; Positive end-expiratory pressure; Stroke volume variations; Cardiac output; Central venous pressure

Key concepts: Medicine, ARDS, Cardiac output, Stroke volume, Mechanical ventilation, Positive end-expiratory pressure, Anesthesia, Ventilation (architecture)

Related papers

Back to paper searchBrowse research topicsOriginal source
Effect of different positive end-expiratory pressure levels on stroke volume variations in patients with acute respiratory distress syndrome treated with mechanical ventilation — Research Paper | ScholarLens