Application of High Performance Liquid Chromatography Method for Triadimenol Analysis in Water Sample
Dadan Hermawan, Cacu Cacu, Suwandri, Amin Fatoni, Mudasir Mudasir, Hassan Y. Aboul‐Enein
Abstract
Open-access reader
Dadan Hermawan, Cacu Cacu, Suwandri, Amin Fatoni, Mudasir Mudasir, Hassan Y. Aboul‐Enein
Abstract
Open-access reader
Abstract Triadimenol is the most important triazole fungicide used for prevention and treatment of plant fungal disease. A simple high performance liquid chromatography (HPLC) method for triadimenol analysis in water sample is reported in this study. The optimized HPLC system using C18 column was achieved using mobile phase composition containing acetonitrile-water (70:30, v/v), a flow rate of 1.0 mL/min, UV detection at 220 nm, and analysis time within 2.5 min. The calibration graph was linear in the range 5 to 50 mg/L with r2 of 0.9997. The limit of detection (LOD) and limit of quantification (LOQ) obtained were 1.23 and 4.12 mg/L, respectively. Combination of solid phase extraction (SPE) and the optimized HPLC method has been successfully applied for the determination of triadimenol in water sample with a recovery of 94.24 % (RSD = 5.38%, n = 4). The proposed HPLC method provides short analysis time, high reproducibility and high sensitivity.
OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Abstract Triadimenol is the most important triazole fungicide used for prevention and treatment of plant fungal disease. A simple high performance liquid chromatography (HPLC) method for triadimenol analysis in water sample is reported in this study. The optimized HPLC system using C18 column was achieved using mobile phase composition containing acetonitrile-water (70:30, v/v), a flow rate of 1.0 mL/min, UV detection at 220 nm, and analysis time within 2.5 min. The calibration graph was linear in the range 5 to 50 mg/L with r2 of 0.9997. The limit of detection (LOD) and limit of quantification (LOQ) obtained were 1.23 and 4.12 mg/L, respectively. Combination of solid phase extraction (SPE) and the optimized HPLC method has been successfully applied for the determination of triadimenol in water sample with a recovery of 94.24 % (RSD = 5.38%, n = 4). The proposed HPLC method provides short analysis time, high reproducibility and high sensitivity.
Key concepts: Chromatography, High-performance liquid chromatography, Detection limit, Reproducibility, Linear range, Chemistry, Calibration curve, Acetonitrile