A phantom study of dose reduction potential in pelvic CT with advanced iterative reconstruction algorithms
Peigang Ning, Dapeng Shi, Cheng Xiaojun, Lv Yumin, Shaocheng Zhu
Abstract
Peigang Ning, Dapeng Shi, Cheng Xiaojun, Lv Yumin, Shaocheng Zhu
Abstract
Objective To assess the dose reduction potential of adaptive statistical iterative reconstruction(ASiR)and model-based iterative reconstruction(MBIR)in pelvic CT with a standard male phantom.Methods A Fluke Biomedical RANDO standard male phantom was scanned with discovery CT750 HD using different tube currents.CT images were reconstructed with FBP,50%ASiR and MBIR.The CT value,the image noise and the contrast-to-noise ratio(CNR)for the sacral vertebra relative to muscle were measured.The volume CT dose indexes(CTDIvo1)and dose-length product(DLP)were recorded.Results Compared with FBP,using 50%ASiR and MBIR had significant reduced image noise and greater CNR.The effective minimal tube currents for displaying sacral vertebra were 250 mA(FBP),180 mA(50%ASiR),and 100 mA(MBIR).With the similar image quality using FBP,the dose was reduced by 28.0% and 59.9% using 50%ASiR and MBIR,respectively.Conclusions Using advanced iterative algorithms can reduce image noise,improve CNR,and reduce the radiation dose in pelvic CT examination. Key words: Tomography; Radiation dose; Reconstruction algorithm; Iterative
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective To assess the dose reduction potential of adaptive statistical iterative reconstruction(ASiR)and model-based iterative reconstruction(MBIR)in pelvic CT with a standard male phantom.Methods A Fluke Biomedical RANDO standard male phantom was scanned with discovery CT750 HD using different tube currents.CT images were reconstructed with FBP,50%ASiR and MBIR.The CT value,the image noise and the contrast-to-noise ratio(CNR)for the sacral vertebra relative to muscle were measured.The volume CT dose indexes(CTDIvo1)and dose-length product(DLP)were recorded.Results Compared with FBP,using 50%ASiR and MBIR had significant reduced image noise and greater CNR.The effective minimal tube currents for displaying sacral vertebra were 250 mA(FBP),180 mA(50%ASiR),and 100 mA(MBIR).With the similar image quality using FBP,the dose was reduced by 28.0% and 59.9% using 50%ASiR and MBIR,respectively.Conclusions Using advanced iterative algorithms can reduce image noise,improve CNR,and reduce the radiation dose in pelvic CT examination. Key words: Tomography; Radiation dose; Reconstruction algorithm; Iterative
Key concepts: Imaging phantom, Iterative reconstruction, Image quality, Image noise, Nuclear medicine, Medicine, Radiation dose, Radon transform