2014Chinese Journal of Thoracic and Cardiovaescular SurgeryRequires access

Comparative clinical study of percutaneous and peratrial device closure of secundum atrial septal defects under single transesophageal echocardiographic guidance

Xiaobo Guo, Hongxin Li, Guo Wenbin, Chengwei Zou, Wenlong Zhang, Zhengjun Wang, Fei Liang

Open publisher page 0 citations

Abstract

Objective This study is to evaluate the advantages between percutaneous and peratrial device closure of secundum atrial septal defects(ASD) under single transesophageal echocardiographic (TEE) guidance.Methods From December 2010 to December 2012,53 patients with the ASD of≤25 mm in diameter underwent percutaneous device closure under simple TEE guidance(the percutaneous group).The device was implanted through the femoral vascular access.Fifty patients with similar age and similar-sized ASD to the percutaneous group,were selected from 350 consecutive patients who underwent peratrial device closure of ASD and assigned to the peratrial group.The ASDs were occluded through a right minithoracotomy approach.The success rate,intracardiac manipulation time,procedural time,postoperative stay and the follow-up results were recorded.Results When the maximum diameter of ASD was < 20 mm,the success rate of both groups was 100%.When the ASD diameter was 20 mm but 25 mm,the success rate was 84% in the percutaneous group and 100% in the peratrial group.Three patients failed in the percutaneous group with the ASD diameter of 20 mm and the aortic rim of 3 mm.They were successfully converted to peratrial device closure.The average intrcardiac manipulation time was(20±7) minutes in the percutaneous group and (5 ± 6) minutes in the peratrial group(P < 0.05).The average procedure time was(24 ± 7) minutes in the percutaneous group and (39 ± 6) minutes in the peratrial group(P < 0.05).The postoperative hospital stay was (3.0 ± 0.8) days in the percutaneous group and(4.7 ± 1.5) days in the peratrial group(P < 0.05).Conclusion The percutaneous device closure of ASD under simple TEE guidance is feasible,safe,and efficacious in patients with the ASD diameter of ≤25 mm.It has the advantages of less trauma,less procedural time,shorter hospital stay and better cosmetic results.However,when the ASD diameter was 20 mm and the aortic rim was 3 mm,the peratrial approach may be a better choice. Key words: Atrial septal defect ;  Echocardiography, transesophageal ;  Minimally invasive surgery ;  Percutaneous

About this research paper

What this paper is about

Objective This study is to evaluate the advantages between percutaneous and peratrial device closure of secundum atrial septal defects(ASD) under single transesophageal echocardiographic (TEE) guidance.Methods From December 2010 to December 2012,53 patients with the ASD of≤25 mm in diameter underwent percutaneous device closure under simple TEE guidance(the percutaneous group).The device was implanted through the femoral vascular access.Fifty patients with similar age and similar-sized ASD to the percutaneous group,were selected from 350 consecutive patients who underwent peratrial device closure of ASD and assigned to the peratrial group.The ASDs were occluded through a right minithoracotomy approach.The success rate,intracardiac manipulation time,procedural time,postoperative stay and the follow-up results were recorded.Results When the maximum diameter of ASD was < 20 mm,the success rate of both groups was 100%.When the ASD diameter was 20 mm but 25 mm,the success rate was 84% in the percutaneous group and 100% in the peratrial group.Three patients failed in the percutaneous group with the ASD diameter of 20 mm and the aortic rim of 3 mm.They were successfully converted to peratrial device closure.The average intrcardiac manipulation time was(20±7) minutes in the percutaneous group and (5 ± 6) minutes in the peratrial group(P < 0.05).The average procedure time was(24 ± 7) minutes in the percutaneous group and (39 ± 6) minutes in the peratrial group(P < 0.05).The postoperative hospital stay was (3.0 ± 0.8) days in the percutaneous group and(4.7 ± 1.5) days in the peratrial group(P < 0.05).Conclusion The percutaneous device closure of ASD under simple TEE guidance is feasible,safe,and efficacious in patients with the ASD diameter of ≤25 mm.It has the advantages of less trauma,less procedural time,shorter hospital stay and better cosmetic results.However,when the ASD diameter was 20 mm and the aortic rim was 3 mm,the peratrial approach may be a better choice. Key words: Atrial septal defect ;  Echocardiography, transesophageal ;  Minimally invasive surgery ;  Percutaneous

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective This study is to evaluate the advantages between percutaneous and peratrial device closure of secundum atrial septal defects(ASD) under single transesophageal echocardiographic (TEE) guidance.Methods From December 2010 to December 2012,53 patients with the ASD of≤25 mm in diameter underwent percutaneous device closure under simple TEE guidance(the percutaneous group).The device was implanted through the femoral vascular access.Fifty patients with similar age and similar-sized ASD to the percutaneous group,were selected from 350 consecutive patients who underwent peratrial device closure of ASD and assigned to the peratrial group.The ASDs were occluded through a right minithoracotomy approach.The success rate,intracardiac manipulation time,procedural time,postoperative stay and the follow-up results were recorded.Results When the maximum diameter of ASD was < 20 mm,the success rate of both groups was 100%.When the ASD diameter was 20 mm but 25 mm,the success rate was 84% in the percutaneous group and 100% in the peratrial group.Three patients failed in the percutaneous group with the ASD diameter of 20 mm and the aortic rim of 3 mm.They were successfully converted to peratrial device closure.The average intrcardiac manipulation time was(20±7) minutes in the percutaneous group and (5 ± 6) minutes in the peratrial group(P < 0.05).The average procedure time was(24 ± 7) minutes in the percutaneous group and (39 ± 6) minutes in the peratrial group(P < 0.05).The postoperative hospital stay was (3.0 ± 0.8) days in the percutaneous group and(4.7 ± 1.5) days in the peratrial group(P < 0.05).Conclusion The percutaneous device closure of ASD under simple TEE guidance is feasible,safe,and efficacious in patients with the ASD diameter of ≤25 mm.It has the advantages of less trauma,less procedural time,shorter hospital stay and better cosmetic results.However,when the ASD diameter was 20 mm and the aortic rim was 3 mm,the peratrial approach may be a better choice. Key words: Atrial septal defect ;  Echocardiography, transesophageal ;  Minimally invasive surgery ;  Percutaneous

Key concepts: Medicine, Percutaneous, Septum secundum, Intracardiac injection, Surgery

Back to paper searchBrowse research topicsOriginal source
Comparative clinical study of percutaneous and peratrial device closure of secundum atrial septal defects under single transesophageal echocardiographic guidance — Research Paper | ScholarLens