2013•Zhonghua fangshe yixue yu fanghu zazhiRequires access

Influence of tumor volume change on intensity modulated radiotherapy for nasopharyngeal carcinoma analyzed by repeated CT simulation

Xue-nan Li, Xia Xiu, Gaofeng Li

Open publisher page 0 citations

Abstract

Objective To analyze the influence of tumor volume change on intensity modulated radiotherapy(IMRT)for nasopharyngeal carcinoma by analyzing the repeated CT simulation.Methods Twenty nasopharyngeal carcinoma patients undergoing IMRT from July 2011 to November 2012 were selected in the study.The first CT simulation was conducted prior to radiotherapy,and the repeated CT simulation was finished after radiotherapy of 30 Gy.The first and the repeated CT images were fused in treatment planning system and GTV volume shrink rate was calculated.The original plan was used to recalculate the dose distribution on repeated CT.The dose volume histogram was used to calculate the dose difference of organs at risk including the brain stem and spinal cord.Results Compared with the first CT,GTV volume shrink rate of the repeated CT simulation was 28.7%,the maximum dose,1 cm3 volume and the average dose percentage of the brain stem and spinal cord were increased(t=0.83-3.17,P<0.05).Conclusions GTV volume shrinked significantly after radiotherapy of 30 Gy in IMRT for nasopharyngeal carcinoma.The dose of the organs at risk increased accordingly. Key words: CT simulation; Intensity modulated radiotherapy; Nasopharyngeal carcinoma; Organ at risk

About this research paper

What this paper is about

Objective To analyze the influence of tumor volume change on intensity modulated radiotherapy(IMRT)for nasopharyngeal carcinoma by analyzing the repeated CT simulation.Methods Twenty nasopharyngeal carcinoma patients undergoing IMRT from July 2011 to November 2012 were selected in the study.The first CT simulation was conducted prior to radiotherapy,and the repeated CT simulation was finished after radiotherapy of 30 Gy.The first and the repeated CT images were fused in treatment planning system and GTV volume shrink rate was calculated.The original plan was used to recalculate the dose distribution on repeated CT.The dose volume histogram was used to calculate the dose difference of organs at risk including the brain stem and spinal cord.Results Compared with the first CT,GTV volume shrink rate of the repeated CT simulation was 28.7%,the maximum dose,1 cm3 volume and the average dose percentage of the brain stem and spinal cord were increased(t=0.83-3.17,P<0.05).Conclusions GTV volume shrinked significantly after radiotherapy of 30 Gy in IMRT for nasopharyngeal carcinoma.The dose of the organs at risk increased accordingly. Key words: CT simulation; Intensity modulated radiotherapy; Nasopharyngeal carcinoma; Organ at risk

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To analyze the influence of tumor volume change on intensity modulated radiotherapy(IMRT)for nasopharyngeal carcinoma by analyzing the repeated CT simulation.Methods Twenty nasopharyngeal carcinoma patients undergoing IMRT from July 2011 to November 2012 were selected in the study.The first CT simulation was conducted prior to radiotherapy,and the repeated CT simulation was finished after radiotherapy of 30 Gy.The first and the repeated CT images were fused in treatment planning system and GTV volume shrink rate was calculated.The original plan was used to recalculate the dose distribution on repeated CT.The dose volume histogram was used to calculate the dose difference of organs at risk including the brain stem and spinal cord.Results Compared with the first CT,GTV volume shrink rate of the repeated CT simulation was 28.7%,the maximum dose,1 cm3 volume and the average dose percentage of the brain stem and spinal cord were increased(t=0.83-3.17,P<0.05).Conclusions GTV volume shrinked significantly after radiotherapy of 30 Gy in IMRT for nasopharyngeal carcinoma.The dose of the organs at risk increased accordingly. Key words: CT simulation; Intensity modulated radiotherapy; Nasopharyngeal carcinoma; Organ at risk

Key concepts: Nasopharyngeal carcinoma, Radiation therapy, Medicine, Nuclear medicine, Spinal cord, Intensity (physics), Carcinoma, Radiology

Related papers

Back to paper searchBrowse research topicsOriginal source
Influence of tumor volume change on intensity modulated radiotherapy for nasopharyngeal carcinoma analyzed by repeated CT simulation — Research Paper | ScholarLens