Clinical study of aspherical toric intraocular lens implantation for correcting corneal high astigmatism in cataract patients
Jing Liu, Lin Xiao, Jingmei Xu
Abstract
Jing Liu, Lin Xiao, Jingmei Xu
Abstract
Objective To evaluate the clinical efficacy of AcrySof SN60AT Toric IOL in correcting pre-operative comeal high astigmatism in cataract patients.Methods This was a retrospective observational study.This study enrolled 20 cases (22 eyes) with cataract combined high astigmatism underwent implantation of AcrySof SN60AT Toric IOL in cataract surgery.The preoperative and postoperative 3 months uncorrected distance visual acuity (UCVA) and best-corrected distance visual acuity (BCVA),postoperative residual astigmatism,and IOL rotational stability after postoperative 1 week,1 month and 3 months were evaluated.Results The postoperative 3 months UCVA was better than BCVA.77% of eyes showed the 0.5.The postoperative residual astigmatism was 0.52± 0.28D and the preoperative residual astigmatism was 0.40±0.25D,there was no statistically difference between them.The mean IOL rotation was (3.69±1.35)o at 3 months follow-up.Conclusions Implantation of high power toric IOL in cataract surgery is a safe,effective and predictable method for correcting corneal high astigmatism. Key words: Corneal astigmatism; Cataract; Aspherical toric IOL
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective To evaluate the clinical efficacy of AcrySof SN60AT Toric IOL in correcting pre-operative comeal high astigmatism in cataract patients.Methods This was a retrospective observational study.This study enrolled 20 cases (22 eyes) with cataract combined high astigmatism underwent implantation of AcrySof SN60AT Toric IOL in cataract surgery.The preoperative and postoperative 3 months uncorrected distance visual acuity (UCVA) and best-corrected distance visual acuity (BCVA),postoperative residual astigmatism,and IOL rotational stability after postoperative 1 week,1 month and 3 months were evaluated.Results The postoperative 3 months UCVA was better than BCVA.77% of eyes showed the 0.5.The postoperative residual astigmatism was 0.52± 0.28D and the preoperative residual astigmatism was 0.40±0.25D,there was no statistically difference between them.The mean IOL rotation was (3.69±1.35)o at 3 months follow-up.Conclusions Implantation of high power toric IOL in cataract surgery is a safe,effective and predictable method for correcting corneal high astigmatism. Key words: Corneal astigmatism; Cataract; Aspherical toric IOL
Key concepts: Medicine, Astigmatism, Intraocular lens, Ophthalmology, Visual acuity, Cataract surgery, Optics, Physics