Feasibility study of automatic tube current modulation technique of 64-slices CT for reducing radiation doses of lower extremity arterial imaging

Guo Ying, Yinghui Ge, Dapeng Shi, Peigang Ning, Wen Zeying, Shouhua Zhang

Open publisher page 0 citations

Abstract

Objective To investigate the value of automatic tube current modulation technique of 64-slices CT for reducing radiation doses of lower extremity arterial imaging. Methods Adjustment tube current through the pre-test changes in the noise index (NI), obtained the image quality and radiation dose with better matches when NI value of 10 HU. Fifty-two diabetic and hypertensive patients suspicious of having lower extremity occlusive disease underwent 64-slices CT volume scan arranged from infra-renal aorta to feet and separated random into 2 groups. The experimental group of 26 patients(FM) used fixed tube current of 300 mA technique, and the the follow-up of 26 patients (control group) used automatic tube current modulation (ATCM) technique with NI= 10. We selected the observing levels at infra-renal aorta, femoral artery of hip joint level, popliteal artery and anterior tibial artery at ankle level. Both sets of image quality, image noise and radiation dose were analyzed by using t-test. Results The radiation dose level of ATCM group[ CTDI_(vol): 10.81 mGy,DLP: (1280.40±124.70) mGy·cm] was lower than FM group[CTDI_(vol): (5.14±1.23) mGy, DLP: (582.86±150.41) mGy·cm] by 54.4% , difference between the two groups was statistically significant(t_(CTDIvol) = 13.13, t_(DLP) = 17.36, P 0.05). Conclusion Lower extremity CT scanning with automatic tube current modulation technique (NI = 10) can greatly reduce the radiation exposure by 54.4% and maintain the equivalent image quality. Key words: Lower extremity; angiography;  Radiation dose;  Image noise;  Tomography;  X-ray computed

About this research paper

What this paper is about

Objective To investigate the value of automatic tube current modulation technique of 64-slices CT for reducing radiation doses of lower extremity arterial imaging. Methods Adjustment tube current through the pre-test changes in the noise index (NI), obtained the image quality and radiation dose with better matches when NI value of 10 HU. Fifty-two diabetic and hypertensive patients suspicious of having lower extremity occlusive disease underwent 64-slices CT volume scan arranged from infra-renal aorta to feet and separated random into 2 groups. The experimental group of 26 patients(FM) used fixed tube current of 300 mA technique, and the the follow-up of 26 patients (control group) used automatic tube current modulation (ATCM) technique with NI= 10. We selected the observing levels at infra-renal aorta, femoral artery of hip joint level, popliteal artery and anterior tibial artery at ankle level. Both sets of image quality, image noise and radiation dose were analyzed by using t-test. Results The radiation dose level of ATCM group[ CTDI_(vol): 10.81 mGy,DLP: (1280.40±124.70) mGy·cm] was lower than FM group[CTDI_(vol): (5.14±1.23) mGy, DLP: (582.86±150.41) mGy·cm] by 54.4% , difference between the two groups was statistically significant(t_(CTDIvol) = 13.13, t_(DLP) = 17.36, P 0.05). Conclusion Lower extremity CT scanning with automatic tube current modulation technique (NI = 10) can greatly reduce the radiation exposure by 54.4% and maintain the equivalent image quality. Key words: Lower extremity; angiography;  Radiation dose;  Image noise;  Tomography;  X-ray computed

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To investigate the value of automatic tube current modulation technique of 64-slices CT for reducing radiation doses of lower extremity arterial imaging. Methods Adjustment tube current through the pre-test changes in the noise index (NI), obtained the image quality and radiation dose with better matches when NI value of 10 HU. Fifty-two diabetic and hypertensive patients suspicious of having lower extremity occlusive disease underwent 64-slices CT volume scan arranged from infra-renal aorta to feet and separated random into 2 groups. The experimental group of 26 patients(FM) used fixed tube current of 300 mA technique, and the the follow-up of 26 patients (control group) used automatic tube current modulation (ATCM) technique with NI= 10. We selected the observing levels at infra-renal aorta, femoral artery of hip joint level, popliteal artery and anterior tibial artery at ankle level. Both sets of image quality, image noise and radiation dose were analyzed by using t-test. Results The radiation dose level of ATCM group[ CTDI_(vol): 10.81 mGy,DLP: (1280.40±124.70) mGy·cm] was lower than FM group[CTDI_(vol): (5.14±1.23) mGy, DLP: (582.86±150.41) mGy·cm] by 54.4% , difference between the two groups was statistically significant(t_(CTDIvol) = 13.13, t_(DLP) = 17.36, P 0.05). Conclusion Lower extremity CT scanning with automatic tube current modulation technique (NI = 10) can greatly reduce the radiation exposure by 54.4% and maintain the equivalent image quality. Key words: Lower extremity; angiography;  Radiation dose;  Image noise;  Tomography;  X-ray computed

Key concepts: Medicine, Image quality, Nuclear medicine, Angiography, Artery, Radiology, Surgery, Image (mathematics)

Related papers

Back to paper searchBrowse research topicsOriginal source
Feasibility study of automatic tube current modulation technique of 64-slices CT for reducing radiation doses of lower extremity arterial imaging — Research Paper | ScholarLens