2008Zhonghua fangshexian yixue zazhiRequires access

Dose reduction using prospective electrocardiograph-triggered axial coronary scan on the 64-slice spiral CT

Yanyan Wang, Guogeng Wu, Cheng Zhou, Sheng Jiao, Cao Hui-zhi

Open publisher page 1 citations

Abstract

Objective To compare radiation dose and image quality between prospective electrocardiograph(ECG)-triggered axial seau and retrospective ECG-gated helical scan in coronary 64-slice CT angiography(CTA).Methods Seventy-seven consecutive patients[group A.Average body mass index (BMI):24.6,heart rate<70 bpm]underwent 64-slice CTA using prospective ECG-triggered axial scan protocol(120 kV,mA tailored to BMI).For each patient,the simulated radiation dose using retrospective ECG-gated scan protocol without ECG-driven X-ray current modulation technology was calculated and recorded at sanle kV and mA.Retrospective ECG-gated scan protocol was performed on 30 consecutive patients in another group(group B.Average BMI:23.9,heart rate<70 bpm).The image quality was blindly evaluated between group A and B(paired t-test was used and P<0.05 as a significant difference).Results There Was a significant difference(t=18.50,P<0.01)between radiation dose of group A (3.37 mSv)and that of group B(18.13 mSv),decreased by 81.4%.The image quality of group A could fulfill clinical diagnostic needs.The average radiation dose of using simulated helical scan without optimization was 17.29 mSv,which wag similar to that of group B(18.13 mSv)(t=0.87,P>0.05).Condusion Prospective ECG-triggered axial scan in 64-slice coronary CTA Call significantly reduce radiation exposure and the image quality can fulfill clinical diagnostic needs. Key words: Tomography,X-ray computed; Coronary vessels; Radiation dosage

About this research paper

What this paper is about

Objective To compare radiation dose and image quality between prospective electrocardiograph(ECG)-triggered axial seau and retrospective ECG-gated helical scan in coronary 64-slice CT angiography(CTA).Methods Seventy-seven consecutive patients[group A.Average body mass index (BMI):24.6,heart rate<70 bpm]underwent 64-slice CTA using prospective ECG-triggered axial scan protocol(120 kV,mA tailored to BMI).For each patient,the simulated radiation dose using retrospective ECG-gated scan protocol without ECG-driven X-ray current modulation technology was calculated and recorded at sanle kV and mA.Retrospective ECG-gated scan protocol was performed on 30 consecutive patients in another group(group B.Average BMI:23.9,heart rate<70 bpm).The image quality was blindly evaluated between group A and B(paired t-test was used and P<0.05 as a significant difference).Results There Was a significant difference(t=18.50,P<0.01)between radiation dose of group A (3.37 mSv)and that of group B(18.13 mSv),decreased by 81.4%.The image quality of group A could fulfill clinical diagnostic needs.The average radiation dose of using simulated helical scan without optimization was 17.29 mSv,which wag similar to that of group B(18.13 mSv)(t=0.87,P>0.05).Condusion Prospective ECG-triggered axial scan in 64-slice coronary CTA Call significantly reduce radiation exposure and the image quality can fulfill clinical diagnostic needs. Key words: Tomography,X-ray computed; Coronary vessels; Radiation dosage

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To compare radiation dose and image quality between prospective electrocardiograph(ECG)-triggered axial seau and retrospective ECG-gated helical scan in coronary 64-slice CT angiography(CTA).Methods Seventy-seven consecutive patients[group A.Average body mass index (BMI):24.6,heart rate<70 bpm]underwent 64-slice CTA using prospective ECG-triggered axial scan protocol(120 kV,mA tailored to BMI).For each patient,the simulated radiation dose using retrospective ECG-gated scan protocol without ECG-driven X-ray current modulation technology was calculated and recorded at sanle kV and mA.Retrospective ECG-gated scan protocol was performed on 30 consecutive patients in another group(group B.Average BMI:23.9,heart rate<70 bpm).The image quality was blindly evaluated between group A and B(paired t-test was used and P<0.05 as a significant difference).Results There Was a significant difference(t=18.50,P<0.01)between radiation dose of group A (3.37 mSv)and that of group B(18.13 mSv),decreased by 81.4%.The image quality of group A could fulfill clinical diagnostic needs.The average radiation dose of using simulated helical scan without optimization was 17.29 mSv,which wag similar to that of group B(18.13 mSv)(t=0.87,P>0.05).Condusion Prospective ECG-triggered axial scan in 64-slice coronary CTA Call significantly reduce radiation exposure and the image quality can fulfill clinical diagnostic needs. Key words: Tomography,X-ray computed; Coronary vessels; Radiation dosage

Key concepts: Medicine, Nuclear medicine, Image quality, Prospective cohort study, Helical scan, Effective dose (radiation), Heart rate, Radiation dose

Related papers

Back to paper searchBrowse research topicsOriginal source
Dose reduction using prospective electrocardiograph-triggered axial coronary scan on the 64-slice spiral CT — Research Paper | ScholarLens