2008•Zhongguo jiceng yiyaoRequires access

Determination of simvastatin and its related substances in simvastatin tablets by HPLC

Haiyan Li, Li-zhen Lin, Ying Zhu

Open publisher page 0 citations

Abstract

Objective To establish an HPLC method for determination of simvastatin and its related substances.Methods The HPLC system consisted Luna C18 column(250mm×4.6mm,5μm),the mobile phase was 0.025mol/L sodium phosphate monobasic(pH 4.5):acetonitrile(35:65).The flow rate wns 1.0ml/min,and with detection 238nm.The column temperature was room temperature;injeetion volume WaS 20μl.Results SimvaStatin and its related substances can be completely separated by the method with a linear range of 2~200μg/ml.Calibration culwe was linear over the range of Y=3.256C×103+4.510×102(r=0.9996);for potency assay the mean recovery rate was 99.32% with RSD as 0.31%(n=9).Conclusion The method has good reproducibility,high accuracy and strong specificity.It was suitable for determination of simvastatin and its related substances. Key words: Simvastatin; HPLC; Determination

About this research paper

What this paper is about

Objective To establish an HPLC method for determination of simvastatin and its related substances.Methods The HPLC system consisted Luna C18 column(250mm×4.6mm,5μm),the mobile phase was 0.025mol/L sodium phosphate monobasic(pH 4.5):acetonitrile(35:65).The flow rate wns 1.0ml/min,and with detection 238nm.The column temperature was room temperature;injeetion volume WaS 20μl.Results SimvaStatin and its related substances can be completely separated by the method with a linear range of 2~200μg/ml.Calibration culwe was linear over the range of Y=3.256C×103+4.510×102(r=0.9996);for potency assay the mean recovery rate was 99.32% with RSD as 0.31%(n=9).Conclusion The method has good reproducibility,high accuracy and strong specificity.It was suitable for determination of simvastatin and its related substances. Key words: Simvastatin; HPLC; Determination

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To establish an HPLC method for determination of simvastatin and its related substances.Methods The HPLC system consisted Luna C18 column(250mm×4.6mm,5μm),the mobile phase was 0.025mol/L sodium phosphate monobasic(pH 4.5):acetonitrile(35:65).The flow rate wns 1.0ml/min,and with detection 238nm.The column temperature was room temperature;injeetion volume WaS 20μl.Results SimvaStatin and its related substances can be completely separated by the method with a linear range of 2~200μg/ml.Calibration culwe was linear over the range of Y=3.256C×103+4.510×102(r=0.9996);for potency assay the mean recovery rate was 99.32% with RSD as 0.31%(n=9).Conclusion The method has good reproducibility,high accuracy and strong specificity.It was suitable for determination of simvastatin and its related substances. Key words: Simvastatin; HPLC; Determination

Key concepts: Simvastatin, Monobasic acid, Chromatography, High-performance liquid chromatography, Reproducibility, Calibration curve, Medicine, Linear range

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of simvastatin and its related substances in simvastatin tablets by HPLC — Research Paper | ScholarLens