Experience of transcanalicular 980nm laser-assisted dacryocystorhinostomy
Yiming Ren, Wei Hong Jiang, Min Qiu, Yan Wu, Fei Han
Abstract
Yiming Ren, Wei Hong Jiang, Min Qiu, Yan Wu, Fei Han
Abstract
Objective To sum up the experience of transcanalicular 980nm laser-assisted dacryocystorhinostomy.Methods Retrospective reviewed 11 cases whom underwent transcanalicular laser-assisted dacryocystorhinostomy combined silicone intubation stenting,including 8 primary nasolacrimal duct obstruction and 3 failed external dacryocystorhinostomy.Follow-up time was 5-17 months.Surgery operation and complication were recorded.Results The size of osteotomys were about 3mm and 4 osteotomys were out of good place.Complications included 8 dacryocystitis,and 6 stenosis or obstruction of lacrimal ductule or common canalicular.Significant improvement of epiphora was achieved in 3 cases at last follow-up.Conclusions The transcanalicular 980nm laser-assisted dacryocystorhinostomy have been reported achieve satisfied success rate.However,experiences are needed for adequate osteotomy size,good location of ostrotomy,avoiding common canalicular thermal injury. Key words: Lacrimal duct obstruction; Transcanalicular laser-assisted dacryocystorhinostomy; 980nm laser
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective To sum up the experience of transcanalicular 980nm laser-assisted dacryocystorhinostomy.Methods Retrospective reviewed 11 cases whom underwent transcanalicular laser-assisted dacryocystorhinostomy combined silicone intubation stenting,including 8 primary nasolacrimal duct obstruction and 3 failed external dacryocystorhinostomy.Follow-up time was 5-17 months.Surgery operation and complication were recorded.Results The size of osteotomys were about 3mm and 4 osteotomys were out of good place.Complications included 8 dacryocystitis,and 6 stenosis or obstruction of lacrimal ductule or common canalicular.Significant improvement of epiphora was achieved in 3 cases at last follow-up.Conclusions The transcanalicular 980nm laser-assisted dacryocystorhinostomy have been reported achieve satisfied success rate.However,experiences are needed for adequate osteotomy size,good location of ostrotomy,avoiding common canalicular thermal injury. Key words: Lacrimal duct obstruction; Transcanalicular laser-assisted dacryocystorhinostomy; 980nm laser
Key concepts: Medicine, Dacryocystorhinostomy, Nasolacrimal duct obstruction, Surgery, Intubation, Stenosis, Nasolacrimal duct, Stent