Objective To evaluate the efficacy of PEEP set according to pressure-volume (P-V) curve for one lung ventilation (OLV) in patients undergoing thoracic surgery.Methods One hundred and twenty ASA Ⅱ or Ⅲ patients of both sexes aged 20-60 yr weighing 40-80 kg undergoing lobectomy under general anesthesia were enrolled in this study.Double lumen tube was inserted.Correct positioning was verified by fiberoptic bronchoscopy.The patients were mechanically ventilated.P-V curve was determined at 3 min of two-lung ventilation (TLV).Lower inflection point (LIP) was measured and the pressure at LIP (PLIP) was recorded.The patients were randomly divided into 5 groups (n = 24 each):control group (group C) and 4 lung protective ventilation regimen groups ( groups P1-4 ).PEEP was set at 0 and VT was set at 10 ml/kg in group C.PEEP was set at 0 and VT was set at 6 ml/kg in group P1.PEEP was set at PLIP- 2 cm H2O and VT was set at 6 ml/kg in group P2.PEEP was set at PLIP and VT was set at 6 ml/kg in group P3.PEEP was set at PLIP + 2 cm H2O and VT was set at 6 ml/kg in group P4.Peak airway pressure (Ppeak),plateau airway pressure (Pplat),airway resistance (Raw) and lung compliance (CL ) were measured and recorded during OLV and TLV after a period of stabilization.Arterial blood samples were taken before induction of anesthesia and at 20 min of TLV and 20 min of OLV for blood gas analysis.Qs/Qt was calculated.Arterial blood samples were collected at the beginning and end of OLV for determination of plasma concentrations of IL-6 and TNF-α(by ELISA).Results Compared with group C,Ppeak and Pplat were significantly increased while Raw was decreased and plasma IL-6 concentration was significantly decreased at the end of OLV in group P4.PaCO2 was significantly higher during TLV and OLV in groups P1-4 than in group C.There was no significant difference in the parameters of respiratory mechanics,blood gases and plasma IL-6 and TNF-α concentrations among groups P1,2.3.Compared with groups P1,2,3,Ppeak and Pplat were significantly increased while plasma IL-6 concentration was decreased at the end of OLV in group P4.Conclusion Mechanical ventilation with VT set at 6ml/kg and PEEP at PLIP + 2 cm H2 O provides best venfilatory efficacy for OLV in terms of oxygenation and inhibition of inflammatory response. Key words: Positive-pressure respiration; Tidal volume
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective To evaluate the efficacy of PEEP set according to pressure-volume (P-V) curve for one lung ventilation (OLV) in patients undergoing thoracic surgery.Methods One hundred and twenty ASA Ⅱ or Ⅲ patients of both sexes aged 20-60 yr weighing 40-80 kg undergoing lobectomy under general anesthesia were enrolled in this study.Double lumen tube was inserted.Correct positioning was verified by fiberoptic bronchoscopy.The patients were mechanically ventilated.P-V curve was determined at 3 min of two-lung ventilation (TLV).Lower inflection point (LIP) was measured and the pressure at LIP (PLIP) was recorded.The patients were randomly divided into 5 groups (n = 24 each):control group (group C) and 4 lung protective ventilation regimen groups ( groups P1-4 ).PEEP was set at 0 and VT was set at 10 ml/kg in group C.PEEP was set at 0 and VT was set at 6 ml/kg in group P1.PEEP was set at PLIP- 2 cm H2O and VT was set at 6 ml/kg in group P2.PEEP was set at PLIP and VT was set at 6 ml/kg in group P3.PEEP was set at PLIP + 2 cm H2O and VT was set at 6 ml/kg in group P4.Peak airway pressure (Ppeak),plateau airway pressure (Pplat),airway resistance (Raw) and lung compliance (CL ) were measured and recorded during OLV and TLV after a period of stabilization.Arterial blood samples were taken before induction of anesthesia and at 20 min of TLV and 20 min of OLV for blood gas analysis.Qs/Qt was calculated.Arterial blood samples were collected at the beginning and end of OLV for determination of plasma concentrations of IL-6 and TNF-α(by ELISA).Results Compared with group C,Ppeak and Pplat were significantly increased while Raw was decreased and plasma IL-6 concentration was significantly decreased at the end of OLV in group P4.PaCO2 was significantly higher during TLV and OLV in groups P1-4 than in group C.There was no significant difference in the parameters of respiratory mechanics,blood gases and plasma IL-6 and TNF-α concentrations among groups P1,2.3.Compared with groups P1,2,3,Ppeak and Pplat were significantly increased while plasma IL-6 concentration was decreased at the end of OLV in group P4.Conclusion Mechanical ventilation with VT set at 6ml/kg and PEEP at PLIP + 2 cm H2 O provides best venfilatory efficacy for OLV in terms of oxygenation and inhibition of inflammatory response. Key words: Positive-pressure respiration; Tidal volume
Key concepts: Medicine, Anesthesia, Ventilation (architecture), Airway, Pulmonary compliance, Positive end-expiratory pressure, Airway resistance, Plateau pressure