Uncomplicated percutaneous IVC filter removal following implantation time of 6033 days
Hans Michell, Gregory Johnston, Christopher S. Morris
Abstract
Open-access reader
Hans Michell, Gregory Johnston, Christopher S. Morris
Abstract
Open-access reader
Most patients have a time limited indication for inferior vena cava filtration. When the indication has expired, a retrievable inferior vena cava filter should be removed percutaneously, unless the risks of retrieval outweigh the benefits. Over time, long term indwelling inferior vena cava filters may experience complications, such as strut penetration, migration, thrombosis, tilt, fracture, and inferior vena cava stenosis. Long term indwelling retrievable inferior vena cava filters may become embedded in the wall of the inferior vena cava, making percutaneous retrieval difficult. However, this is not always the case, and they also may be easily and safely removed using simple techniques. We present a case of a long term indwelling retrievable inferior vena cava filter that was easily removed using simple techniques, 16.5 years after placement.
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Most patients have a time limited indication for inferior vena cava filtration. When the indication has expired, a retrievable inferior vena cava filter should be removed percutaneously, unless the risks of retrieval outweigh the benefits. Over time, long term indwelling inferior vena cava filters may experience complications, such as strut penetration, migration, thrombosis, tilt, fracture, and inferior vena cava stenosis. Long term indwelling retrievable inferior vena cava filters may become embedded in the wall of the inferior vena cava, making percutaneous retrieval difficult. However, this is not always the case, and they also may be easily and safely removed using simple techniques. We present a case of a long term indwelling retrievable inferior vena cava filter that was easily removed using simple techniques, 16.5 years after placement.
Key concepts: Medicine, Inferior vena cava, Inferior vena cava filter, Percutaneous, Thrombosis, Radiology, Surgery, Stenosis