2018•PubMedRequires access

[Effects of Long-term Side Stream Extracton on Phosphorus Removal and Recovery Performance of EBPR System].

Xiao-Jun Yu, Jie Li, Meng Zhou, Song Wei Lu, Wei-Wei Li, Ya-E Wang, Juan Ma, Hui Min Lu

Open publisher page 0 citations

Abstract

-N were found to be relatively stable over the entire experimental period and effluent could meet standard A of the national discharge standard of pollutants for municipal wastewater treatment plants. Total nitrogen removal improved due to enhancement of denitrification capability during the anaerobic phase, and the standard-reaching rate increased from 88.2% to 98.6%. Although phosphate releasing capability gradually decreased, phosphorus removal performances of the former two runs were stable and efficient. The removal rate was>90% and the corresponding standard-reaching rate was>75%. Nevertheless, phosphorus removal performance began to fluctuate with a side stream ratio of 1/2 during the third run. The lowest phosphorus removal rate was 54.2%, contributing to a 60% non-standard-reaching rate in this run. This suggests that long-term extraction of 1/2 side stream supernatant is not favorable for maintaining stable effluent of the main process. It was also found that long-term phosphate recovery through side stream extraction allowed reduction of sludge mass and had little impact on sludge settling performance. As a result, it is feasible to extract an appropriate side stream ratio of anaerobic supernatant to recover phosphate, combined with efficient removal of both nitrogen and phosphorus in the main process.

About this research paper

What this paper is about

-N were found to be relatively stable over the entire experimental period and effluent could meet standard A of the national discharge standard of pollutants for municipal wastewater treatment plants. Total nitrogen removal improved due to enhancement of denitrification capability during the anaerobic phase, and the standard-reaching rate increased from 88.2% to 98.6%. Although phosphate releasing capability gradually decreased, phosphorus removal performances of the former two runs were stable and efficient. The removal rate was>90% and the corresponding standard-reaching rate was>75%. Nevertheless, phosphorus removal performance began to fluctuate with a side stream ratio of 1/2 during the third run. The lowest phosphorus removal rate was 54.2%, contributing to a 60% non-standard-reaching rate in this run. This suggests that long-term extraction of 1/2 side stream supernatant is not favorable for maintaining stable effluent of the main process. It was also found that long-term phosphate recovery through side stream extraction allowed reduction of sludge mass and had little impact on sludge settling performance. As a result, it is feasible to extract an appropriate side stream ratio of anaerobic supernatant to recover phosphate, combined with efficient removal of both nitrogen and phosphorus in the main process.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

-N were found to be relatively stable over the entire experimental period and effluent could meet standard A of the national discharge standard of pollutants for municipal wastewater treatment plants. Total nitrogen removal improved due to enhancement of denitrification capability during the anaerobic phase, and the standard-reaching rate increased from 88.2% to 98.6%. Although phosphate releasing capability gradually decreased, phosphorus removal performances of the former two runs were stable and efficient. The removal rate was>90% and the corresponding standard-reaching rate was>75%. Nevertheless, phosphorus removal performance began to fluctuate with a side stream ratio of 1/2 during the third run. The lowest phosphorus removal rate was 54.2%, contributing to a 60% non-standard-reaching rate in this run. This suggests that long-term extraction of 1/2 side stream supernatant is not favorable for maintaining stable effluent of the main process. It was also found that long-term phosphate recovery through side stream extraction allowed reduction of sludge mass and had little impact on sludge settling performance. As a result, it is feasible to extract an appropriate side stream ratio of anaerobic supernatant to recover phosphate, combined with efficient removal of both nitrogen and phosphorus in the main process.

Key concepts: Effluent, Enhanced biological phosphorus removal, Sequencing batch reactor, Phosphorus, Anaerobic exercise, Chemistry, Wastewater, Pulp and paper industry

Related papers

Back to paper searchBrowse research topicsOriginal source
[Effects of Long-term Side Stream Extracton on Phosphorus Removal and Recovery Performance of EBPR System]. — Research Paper | ScholarLens