2020American MineralogistOpen access

In-situ measurements of magmatic volatile elements, F, S, and Cl, by electron microprobe, secondary ion mass spectrometry, and heavy ion elastic recoil detection analysis

Estelle F. Rose Koga, Kenneth T. Koga, Jean‐Luc Devidal, Nobumichi Shimizu, M. Le Voyer, Célia Dalou, M. Döbeli

Open full text 24 citations

Abstract

Abstract Electron probe and ion probe are the two most used instruments for in situ analysis of halogens in geological materials. The comparison of these two methods on widely distributed glass standards (example: MPI-DING glasses, Jochum et al., G-cubed, 2006) provides a basis for establishing laboratory method, independent geochemical data sets for these elements. We report analyses of F, S, and Cl concentrations in three geological glass samples (EPMA) and 10 referenced standards (EPMA and SIMS). Furthermore, F and Cl absolute abundances have been determined independently for three of the standards (KL2-G, ATHO-G, and KE12), via heavy ion elastic recoil detection analysis (HIERDA), to certify the accuracy of the cross-calibration EPMA-SIMS. The detection limits for EPMA are a 150 μg·g-1 for F, 20 μg·g-1 for S and Cl, and for SIMS < 48 μg·g-1 for F, < 3 μg·g-1 for S, and <19 μg·g-1 for Cl. On SiO2-rich glass-standards, F and Cl measurements by HIERDA highlight a weak matrix effect during SIMS analysis of F and Cl. With the HIERDA independently measured value, we therefore propose an alternative calibration function to empirically correct this matrix effect on the SIMS measurements of F, S, and Cl.

About this research paper

What this paper is about

Abstract Electron probe and ion probe are the two most used instruments for in situ analysis of halogens in geological materials. The comparison of these two methods on widely distributed glass standards (example: MPI-DING glasses, Jochum et al., G-cubed, 2006) provides a basis for establishing laboratory method, independent geochemical data sets for these elements. We report analyses of F, S, and Cl concentrations in three geological glass samples (EPMA) and 10 referenced standards (EPMA and SIMS). Furthermore, F and Cl absolute abundances have been determined independently for three of the standards (KL2-G, ATHO-G, and KE12), via heavy ion elastic recoil detection analysis (HIERDA), to certify the accuracy of the cross-calibration EPMA-SIMS. The detection limits for EPMA are a 150 μg·g-1 for F, 20 μg·g-1 for S and Cl, and for SIMS < 48 μg·g-1 for F, < 3 μg·g-1 for S, and <19 μg·g-1 for Cl. On SiO2-rich glass-standards, F and Cl measurements by HIERDA highlight a weak matrix effect during SIMS analysis of F and Cl. With the HIERDA independently measured value, we therefore propose an alternative calibration function to empirically correct this matrix effect on the SIMS measurements of F, S, and Cl.

Why it matters

OpenAlex reports 24 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract Electron probe and ion probe are the two most used instruments for in situ analysis of halogens in geological materials. The comparison of these two methods on widely distributed glass standards (example: MPI-DING glasses, Jochum et al., G-cubed, 2006) provides a basis for establishing laboratory method, independent geochemical data sets for these elements. We report analyses of F, S, and Cl concentrations in three geological glass samples (EPMA) and 10 referenced standards (EPMA and SIMS). Furthermore, F and Cl absolute abundances have been determined independently for three of the standards (KL2-G, ATHO-G, and KE12), via heavy ion elastic recoil detection analysis (HIERDA), to certify the accuracy of the cross-calibration EPMA-SIMS. The detection limits for EPMA are a 150 μg·g-1 for F, 20 μg·g-1 for S and Cl, and for SIMS < 48 μg·g-1 for F, < 3 μg·g-1 for S, and <19 μg·g-1 for Cl. On SiO2-rich glass-standards, F and Cl measurements by HIERDA highlight a weak matrix effect during SIMS analysis of F and Cl. With the HIERDA independently measured value, we therefore propose an alternative calibration function to empirically correct this matrix effect on the SIMS measurements of F, S, and Cl.

Key concepts: Electron microprobe, Analytical Chemistry (journal), Elastic recoil detection, Secondary ion mass spectrometry, Microprobe, Ion, Chemistry, Mass spectrometry

Related papers

Back to paper searchBrowse research topicsOriginal source
In-situ measurements of magmatic volatile elements, F, S, and Cl, by electron microprobe, secondary ion mass spectrometry, and heavy ion elastic recoil detection analysis — Research Paper | ScholarLens