2020Middle East African Journal of OphthalmologyOpen access

Safety and efficacy of ahmed valve on intractable glaucoma in Saudi population

Essam A. Osman, Norah F Alkheraiji, Mohammad A. Abouammoh, Ahmed Mousa, Saleh A. Al‐Obeidan

Open full text 4 citations

Abstract

PURPOSE: The study aims to assess the efficacy and safety of Ahmed glaucoma valve implant in eyes with intractable glaucoma and to evaluate the risk factors for failure. METHODS: A retrospective evaluation of 83 patients (117 eyes) with intractable glaucoma who underwent silicone Ahmed glaucoma valve implant was done in a tertiary care center in Riyadh, Saudi Arabia, between January 2014 and December 2016. Complete success was defined as intraocular pressure (IOP) ≤21 mmHg without medication after a minimum follow-up of 6 months. RESULTS: = 0.006, 0.040, and 0.014, respectively). CONCLUSIONS: Ahmed glaucoma valve implant was safe and effective in treating cases of intractable glaucoma.

About this research paper

What this paper is about

PURPOSE: The study aims to assess the efficacy and safety of Ahmed glaucoma valve implant in eyes with intractable glaucoma and to evaluate the risk factors for failure. METHODS: A retrospective evaluation of 83 patients (117 eyes) with intractable glaucoma who underwent silicone Ahmed glaucoma valve implant was done in a tertiary care center in Riyadh, Saudi Arabia, between January 2014 and December 2016. Complete success was defined as intraocular pressure (IOP) ≤21 mmHg without medication after a minimum follow-up of 6 months. RESULTS: = 0.006, 0.040, and 0.014, respectively). CONCLUSIONS: Ahmed glaucoma valve implant was safe and effective in treating cases of intractable glaucoma.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: The study aims to assess the efficacy and safety of Ahmed glaucoma valve implant in eyes with intractable glaucoma and to evaluate the risk factors for failure. METHODS: A retrospective evaluation of 83 patients (117 eyes) with intractable glaucoma who underwent silicone Ahmed glaucoma valve implant was done in a tertiary care center in Riyadh, Saudi Arabia, between January 2014 and December 2016. Complete success was defined as intraocular pressure (IOP) ≤21 mmHg without medication after a minimum follow-up of 6 months. RESULTS: = 0.006, 0.040, and 0.014, respectively). CONCLUSIONS: Ahmed glaucoma valve implant was safe and effective in treating cases of intractable glaucoma.

Key concepts: Medicine, Glaucoma valve, Hyphema, Glaucoma, Intraocular pressure, Implant, Ophthalmology, Glaucoma medication

Related papers

Back to paper searchBrowse research topicsOriginal source
Safety and efficacy of ahmed valve on intractable glaucoma in Saudi population — Research Paper | ScholarLens