2020•Environmental Sciences EuropeOpen access

Complex odor control based on ozonation/GAC advanced treatment: optimization and application in one full-scale water treatment plant

Ping Xia, Shuangyi Zhang, Jianwei Yu, Hui Ye, Dong Zhang, Lei Jiang, Zheng Wang, Daqiang Yin

Open full text 23 citations

Abstract

Abstract Background Taste and odor problem in drinking water is one major concern for consumers and water supply. Exploring the odor characteristics and the major odor causing compounds in the source water is the base for odor control in drinking water treatment plant (WTP). In this study, focusing on a newly constructed reservoir with Huangpu River as the source water, the occurrence of typical odorants and their variations were first identified. Correspondingly, the removal behavior in an ozone/GAC advanced treatment process was investigated. Results The results indicated that 2-methylisoborneol (2-MIB), geosmin (GSM), and bis (2-chloroisopropyl) ether (BCIE) have major contribution to the musty/earthy and chemical/septic odors in the source water, respectively. Pre-ozonation alone (1 mg L−1) showed limited removal for 2-MIB and BCIE, at less than 30% and 20%, respectively, while combining with coagulation, sedimentation, and sand filtration, the removals were improved to higher than 50%. After post-ozonation, the desired removal was achieved at a 1.5 mg L−1 dosage with all the odorants decreased below the corresponding odor threshold concentrations (OTCs) in the effluents. Furthermore, at a 1 mg L−1 post-ozone addition, by combining with subsequent GAC process, the odor problem was solved as well. Conclusion To resolve the odor problem in the drinking water, the concentrations of the odorants at less than their OTCs need to be achieved. As 2-MIB and BCIE have low reactivity towards direct ozonation, a subsequent GAC is needed with a moderate dosage of post-ozonation (1 mg L−1). Thus, for the odor problem in the source water, the suggested operation is: 1 mg L−1 of pre-ozonation in combination with coagulation, sedimentation, and sand filtration, followed by a 1 mg L−1 dosage of post-ozonation and finished by a GAC process.

Open-access reader

About this research paper

What this paper is about

Abstract Background Taste and odor problem in drinking water is one major concern for consumers and water supply. Exploring the odor characteristics and the major odor causing compounds in the source water is the base for odor control in drinking water treatment plant (WTP). In this study, focusing on a newly constructed reservoir with Huangpu River as the source water, the occurrence of typical odorants and their variations were first identified. Correspondingly, the removal behavior in an ozone/GAC advanced treatment process was investigated. Results The results indicated that 2-methylisoborneol (2-MIB), geosmin (GSM), and bis (2-chloroisopropyl) ether (BCIE) have major contribution to the musty/earthy and chemical/septic odors in the source water, respectively. Pre-ozonation alone (1 mg L−1) showed limited removal for 2-MIB and BCIE, at less than 30% and 20%, respectively, while combining with coagulation, sedimentation, and sand filtration, the removals were improved to higher than 50%. After post-ozonation, the desired removal was achieved at a 1.5 mg L−1 dosage with all the odorants decreased below the corresponding odor threshold concentrations (OTCs) in the effluents. Furthermore, at a 1 mg L−1 post-ozone addition, by combining with subsequent GAC process, the odor problem was solved as well. Conclusion To resolve the odor problem in the drinking water, the concentrations of the odorants at less than their OTCs need to be achieved. As 2-MIB and BCIE have low reactivity towards direct ozonation, a subsequent GAC is needed with a moderate dosage of post-ozonation (1 mg L−1). Thus, for the odor problem in the source water, the suggested operation is: 1 mg L−1 of pre-ozonation in combination with coagulation, sedimentation, and sand filtration, followed by a 1 mg L−1 dosage of post-ozonation and finished by a GAC process.

Why it matters

OpenAlex reports 23 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract Background Taste and odor problem in drinking water is one major concern for consumers and water supply. Exploring the odor characteristics and the major odor causing compounds in the source water is the base for odor control in drinking water treatment plant (WTP). In this study, focusing on a newly constructed reservoir with Huangpu River as the source water, the occurrence of typical odorants and their variations were first identified. Correspondingly, the removal behavior in an ozone/GAC advanced treatment process was investigated. Results The results indicated that 2-methylisoborneol (2-MIB), geosmin (GSM), and bis (2-chloroisopropyl) ether (BCIE) have major contribution to the musty/earthy and chemical/septic odors in the source water, respectively. Pre-ozonation alone (1 mg L−1) showed limited removal for 2-MIB and BCIE, at less than 30% and 20%, respectively, while combining with coagulation, sedimentation, and sand filtration, the removals were improved to higher than 50%. After post-ozonation, the desired removal was achieved at a 1.5 mg L−1 dosage with all the odorants decreased below the corresponding odor threshold concentrations (OTCs) in the effluents. Furthermore, at a 1 mg L−1 post-ozone addition, by combining with subsequent GAC process, the odor problem was solved as well. Conclusion To resolve the odor problem in the drinking water, the concentrations of the odorants at less than their OTCs need to be achieved. As 2-MIB and BCIE have low reactivity towards direct ozonation, a subsequent GAC is needed with a moderate dosage of post-ozonation (1 mg L−1). Thus, for the odor problem in the source water, the suggested operation is: 1 mg L−1 of pre-ozonation in combination with coagulation, sedimentation, and sand filtration, followed by a 1 mg L−1 dosage of post-ozonation and finished by a GAC process.

Key concepts: Geosmin, Odor, Water treatment, Chemistry, Ozone, Environmental chemistry, Effluent, Filtration (mathematics)

Related papers

Back to paper searchBrowse research topicsOriginal source
Complex odor control based on ozonation/GAC advanced treatment: optimization and application in one full-scale water treatment plant — Research Paper | ScholarLens