2020•Head & Face MedicineOpen access

Comparison of the accuracy of different impression procedures in case of multiple and angulated implants

M Wafa Richi, Sevcan Kurtulmuş-Yılmaz, Oğuz Ozan

Open full text 30 citations

Abstract

BACKGROUND: There is no consensus in the literature regarding the impression procedures in the presence of multiple and angulated implants. METHODS: Three maxillary master models with 6 implants bilaterally positioned in anterior, premolar and molar regions were fabricated. In model 1, all implants were placed in parallel; in models 2 and 3, anterior implants were buccally inclined and posterior implants were distally inclined in 10- and 20-degrees, respectively. Three different impression copings (hexed, non-hex, multi-unit) and two different impression techniques (splinting and non-splinting) were tested. A total of 180 impressions (n = 10 per group) were made using mono-phase vinyl poly-siloxane. Master models and duplicate casts were scanned by a 5-axis laboratory scanner and data were transferred to a software program for the alignment of master and duplicate copings. Coronal and angular deviations were calculated, and data were statistically analyzed. RESULTS: For angulated models, the lowest deviation values were detected at the splinted non-hex coping group (P < 0.05). CONCLUSIONS: Implant angulation, impression coping type, and splinting the impression copings had significant effects on the accuracy of impressions. TRIAL REGISTRATION: Not applicable.

About this research paper

What this paper is about

BACKGROUND: There is no consensus in the literature regarding the impression procedures in the presence of multiple and angulated implants. METHODS: Three maxillary master models with 6 implants bilaterally positioned in anterior, premolar and molar regions were fabricated. In model 1, all implants were placed in parallel; in models 2 and 3, anterior implants were buccally inclined and posterior implants were distally inclined in 10- and 20-degrees, respectively. Three different impression copings (hexed, non-hex, multi-unit) and two different impression techniques (splinting and non-splinting) were tested. A total of 180 impressions (n = 10 per group) were made using mono-phase vinyl poly-siloxane. Master models and duplicate casts were scanned by a 5-axis laboratory scanner and data were transferred to a software program for the alignment of master and duplicate copings. Coronal and angular deviations were calculated, and data were statistically analyzed. RESULTS: For angulated models, the lowest deviation values were detected at the splinted non-hex coping group (P < 0.05). CONCLUSIONS: Implant angulation, impression coping type, and splinting the impression copings had significant effects on the accuracy of impressions. TRIAL REGISTRATION: Not applicable.

Why it matters

OpenAlex reports 30 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: There is no consensus in the literature regarding the impression procedures in the presence of multiple and angulated implants. METHODS: Three maxillary master models with 6 implants bilaterally positioned in anterior, premolar and molar regions were fabricated. In model 1, all implants were placed in parallel; in models 2 and 3, anterior implants were buccally inclined and posterior implants were distally inclined in 10- and 20-degrees, respectively. Three different impression copings (hexed, non-hex, multi-unit) and two different impression techniques (splinting and non-splinting) were tested. A total of 180 impressions (n = 10 per group) were made using mono-phase vinyl poly-siloxane. Master models and duplicate casts were scanned by a 5-axis laboratory scanner and data were transferred to a software program for the alignment of master and duplicate copings. Coronal and angular deviations were calculated, and data were statistically analyzed. RESULTS: For angulated models, the lowest deviation values were detected at the splinted non-hex coping group (P < 0.05). CONCLUSIONS: Implant angulation, impression coping type, and splinting the impression copings had significant effects on the accuracy of impressions. TRIAL REGISTRATION: Not applicable.

Key concepts: Medicine, Otorhinolaryngology, Oral and maxillofacial surgery, Head and neck surgery, Impression, Dentistry, Medical physics, Orthodontics

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison of the accuracy of different impression procedures in case of multiple and angulated implants — Research Paper | ScholarLens