2020European Journal of Cardio-Thoracic SurgeryOpen access

Development of a multivariable prediction model for patient-adjusted aortic risk morphology

Tobias Krüger, Rodrigo Sandoval Boburg, Hasan Hamdoun, Alexandre Oikonomou, Malte N. Bongers, Christian Schlensak

Open full text 9 citations

Abstract

OBJECTIVES: Preventing type A aortic dissection requires reliable prediction. We developed and validated a multivariable prediction model based on anthropometry to define patient-adjusted thresholds for aortic diameter and length. METHODS: We analysed computed tomography angiographies and clinical data from 510 control patients, 143 subjects for model validation, 125 individuals with ascending aorta ectasia (45-54 mm), 58 patients with aneurysm (≥55 mm), 206 patients with type A aortic dissection and 19 patients who had received a computed tomography angiography ≤2 years before they suffered from a type A aortic dissection. Computed tomography angiographies were analysed using curved planar reformations. RESULTS: In the control group, the mean ascending aortic diameter was 33.8 mm [standard deviation (SD) ±5.2 mm], and the length, measured from the aortic valve to the brachiocephalic trunk, was 91.9 mm (SD ±12.2 mm); both diameter and length were correlated with anthropometric parameters and were smaller than the respective values in all pathological groups (P < 0.001). Multivariable linear regression analysis of the control group revealed that age, sex and body surface area were predictors of ascending aorta diameter (R2 = 0.40) and length (R2 = 0.26). Bicuspidity of the aortic valve was not included in the model; its prevalence was only 3.2% in the control group but >25% in the ectasia and aneurysm groups. CONCLUSIONS: The regression model provides a patient-adjusted prediction of the thresholds for aortic diameter and length. In our retrospective data, the model resulted in better identification of aortas at the risk of dissection than the conventional 55-mm diameter threshold. The model is available as an Internet calculator (www.aorticcalculator.com).

Open-access reader

About this research paper

What this paper is about

OBJECTIVES: Preventing type A aortic dissection requires reliable prediction. We developed and validated a multivariable prediction model based on anthropometry to define patient-adjusted thresholds for aortic diameter and length. METHODS: We analysed computed tomography angiographies and clinical data from 510 control patients, 143 subjects for model validation, 125 individuals with ascending aorta ectasia (45-54 mm), 58 patients with aneurysm (≥55 mm), 206 patients with type A aortic dissection and 19 patients who had received a computed tomography angiography ≤2 years before they suffered from a type A aortic dissection. Computed tomography angiographies were analysed using curved planar reformations. RESULTS: In the control group, the mean ascending aortic diameter was 33.8 mm [standard deviation (SD) ±5.2 mm], and the length, measured from the aortic valve to the brachiocephalic trunk, was 91.9 mm (SD ±12.2 mm); both diameter and length were correlated with anthropometric parameters and were smaller than the respective values in all pathological groups (P < 0.001). Multivariable linear regression analysis of the control group revealed that age, sex and body surface area were predictors of ascending aorta diameter (R2 = 0.40) and length (R2 = 0.26). Bicuspidity of the aortic valve was not included in the model; its prevalence was only 3.2% in the control group but >25% in the ectasia and aneurysm groups. CONCLUSIONS: The regression model provides a patient-adjusted prediction of the thresholds for aortic diameter and length. In our retrospective data, the model resulted in better identification of aortas at the risk of dissection than the conventional 55-mm diameter threshold. The model is available as an Internet calculator (www.aorticcalculator.com).

Why it matters

OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVES: Preventing type A aortic dissection requires reliable prediction. We developed and validated a multivariable prediction model based on anthropometry to define patient-adjusted thresholds for aortic diameter and length. METHODS: We analysed computed tomography angiographies and clinical data from 510 control patients, 143 subjects for model validation, 125 individuals with ascending aorta ectasia (45-54 mm), 58 patients with aneurysm (≥55 mm), 206 patients with type A aortic dissection and 19 patients who had received a computed tomography angiography ≤2 years before they suffered from a type A aortic dissection. Computed tomography angiographies were analysed using curved planar reformations. RESULTS: In the control group, the mean ascending aortic diameter was 33.8 mm [standard deviation (SD) ±5.2 mm], and the length, measured from the aortic valve to the brachiocephalic trunk, was 91.9 mm (SD ±12.2 mm); both diameter and length were correlated with anthropometric parameters and were smaller than the respective values in all pathological groups (P < 0.001). Multivariable linear regression analysis of the control group revealed that age, sex and body surface area were predictors of ascending aorta diameter (R2 = 0.40) and length (R2 = 0.26). Bicuspidity of the aortic valve was not included in the model; its prevalence was only 3.2% in the control group but >25% in the ectasia and aneurysm groups. CONCLUSIONS: The regression model provides a patient-adjusted prediction of the thresholds for aortic diameter and length. In our retrospective data, the model resulted in better identification of aortas at the risk of dissection than the conventional 55-mm diameter threshold. The model is available as an Internet calculator (www.aorticcalculator.com).

Key concepts: Ascending aorta, Medicine, Aortic dissection, Ectasia, Aneurysm, Aorta, Cardiology, Aortic valve

Related papers

Back to paper searchBrowse research topicsOriginal source
Development of a multivariable prediction model for patient-adjusted aortic risk morphology — Research Paper | ScholarLens