2011Journal of Chromatography ARequires access

Determination of Rhodamine 123 in rat plasma utilizing liquid chromatography–tandem mass spectrometry

Yabin Sun, Wen Yu-guan, Yuan Yan, Guofeng Li

Open publisher page 0 citations

Abstract

Rhodamine 123 (R123), as a typical of P-gp substrate, was widely used to quantify P-glycoprotein (P-gp) functional efflux activity in vivo. A new, rapid and sensitive method was developed for quantifying R123 in rat plasma using liquid chromatography–tandem mass spectrometry (LC–MS/MS). R123 and Rhodamine 6G (R6G, the internal standard, IS) were extracted from aliquots of plasma with ethyl acetate and dichloromethane (4:1) as the solvent and chromatographic separation was performed using a Zorbax Eclipse Plus C18 column. The mobile phase was composed of A: ammonium formate–formic acid buffer containing 5mM ammonium formate and 0.1% formic acid and B: methanol (A:B, 5:95, v/v). To quantify R123 and IS respectively, multiple reaction monitoring (MRM) transition of m/z 345.2→285.2 and m/z 443.3→415.2 was performed. The analysis time was 4min in positive mode; the calibration curve was linear in the concentration range of 1–200ng/ml. The lowest limit of quantification (LLOQ) reached 1ng/ml. The intra and inter-day precision were less than 9.2% for the low quality control (QC) level, and 3.4% for other QC levels, respectively, while the intra and inter-day relative errors ranged between −7.4% and 9.1% for three QC concentration levels. The LC–MS/MS method proved to be simple, accurate, reliable and with a shorter running time and has been successfully applied to evaluate the functional activity of P-glycoprotein in an absorption experiment in the rat.

About this research paper

What this paper is about

Rhodamine 123 (R123), as a typical of P-gp substrate, was widely used to quantify P-glycoprotein (P-gp) functional efflux activity in vivo. A new, rapid and sensitive method was developed for quantifying R123 in rat plasma using liquid chromatography–tandem mass spectrometry (LC–MS/MS). R123 and Rhodamine 6G (R6G, the internal standard, IS) were extracted from aliquots of plasma with ethyl acetate and dichloromethane (4:1) as the solvent and chromatographic separation was performed using a Zorbax Eclipse Plus C18 column. The mobile phase was composed of A: ammonium formate–formic acid buffer containing 5mM ammonium formate and 0.1% formic acid and B: methanol (A:B, 5:95, v/v). To quantify R123 and IS respectively, multiple reaction monitoring (MRM) transition of m/z 345.2→285.2 and m/z 443.3→415.2 was performed. The analysis time was 4min in positive mode; the calibration curve was linear in the concentration range of 1–200ng/ml. The lowest limit of quantification (LLOQ) reached 1ng/ml. The intra and inter-day precision were less than 9.2% for the low quality control (QC) level, and 3.4% for other QC levels, respectively, while the intra and inter-day relative errors ranged between −7.4% and 9.1% for three QC concentration levels. The LC–MS/MS method proved to be simple, accurate, reliable and with a shorter running time and has been successfully applied to evaluate the functional activity of P-glycoprotein in an absorption experiment in the rat.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Rhodamine 123 (R123), as a typical of P-gp substrate, was widely used to quantify P-glycoprotein (P-gp) functional efflux activity in vivo. A new, rapid and sensitive method was developed for quantifying R123 in rat plasma using liquid chromatography–tandem mass spectrometry (LC–MS/MS). R123 and Rhodamine 6G (R6G, the internal standard, IS) were extracted from aliquots of plasma with ethyl acetate and dichloromethane (4:1) as the solvent and chromatographic separation was performed using a Zorbax Eclipse Plus C18 column. The mobile phase was composed of A: ammonium formate–formic acid buffer containing 5mM ammonium formate and 0.1% formic acid and B: methanol (A:B, 5:95, v/v). To quantify R123 and IS respectively, multiple reaction monitoring (MRM) transition of m/z 345.2→285.2 and m/z 443.3→415.2 was performed. The analysis time was 4min in positive mode; the calibration curve was linear in the concentration range of 1–200ng/ml. The lowest limit of quantification (LLOQ) reached 1ng/ml. The intra and inter-day precision were less than 9.2% for the low quality control (QC) level, and 3.4% for other QC levels, respectively, while the intra and inter-day relative errors ranged between −7.4% and 9.1% for three QC concentration levels. The LC–MS/MS method proved to be simple, accurate, reliable and with a shorter running time and has been successfully applied to evaluate the functional activity of P-glycoprotein in an absorption experiment in the rat.

Key concepts: Chemistry, Chromatography, Ammonium formate, Formic acid, Mass spectrometry, Calibration curve, Selected reaction monitoring, Detection limit

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Rhodamine 123 in rat plasma utilizing liquid chromatography–tandem mass spectrometry — Research Paper | ScholarLens