2020HKIE TransactionsOpen access

Ideal position and size selection of unified power flow controllers (UPFCs) to upgrade the dynamic stability of systems: An antlion optimiser and invasive weed optimisation Algorithm

Mythili Shanmugam, P. Rajesh

Open full text 219 citations

Abstract

This paper proposes a hybrid methodology to improve the dynamic strength of frameworks by optimally locating and sizing the unified power flow controller (UPFC). The proposed method combines both the antlion optimiser (ALO) and invasive weed optimisation (IWO) techniques. The advantages of the proposed methodology are enhanced searching ability, better identification of optimal solutions and greater reliability. Initially, to locate UPFCs, using the ALO technique, the most extreme power loss bus is recognised as the optimal location. The capacity required to resolve the situation is determined by the IWO technique based on the minimum power loss, voltage deviation and establishment cost of the UPFCs. The proposed system is actualised and aims at the matrix laboratory (MATLAB) environment, while the power flow security and voltage stability are evaluated on the basis of the Institute of Electrical and Electronics Engineers (IEEE) standard benchmark system. At this point, voltage stability, power loss, overloading and UPFC costs are analysed through changing the system load and generation. The proposed working method is then assessed and compared with traditional techniques.

Open-access reader

About this research paper

What this paper is about

This paper proposes a hybrid methodology to improve the dynamic strength of frameworks by optimally locating and sizing the unified power flow controller (UPFC). The proposed method combines both the antlion optimiser (ALO) and invasive weed optimisation (IWO) techniques. The advantages of the proposed methodology are enhanced searching ability, better identification of optimal solutions and greater reliability. Initially, to locate UPFCs, using the ALO technique, the most extreme power loss bus is recognised as the optimal location. The capacity required to resolve the situation is determined by the IWO technique based on the minimum power loss, voltage deviation and establishment cost of the UPFCs. The proposed system is actualised and aims at the matrix laboratory (MATLAB) environment, while the power flow security and voltage stability are evaluated on the basis of the Institute of Electrical and Electronics Engineers (IEEE) standard benchmark system. At this point, voltage stability, power loss, overloading and UPFC costs are analysed through changing the system load and generation. The proposed working method is then assessed and compared with traditional techniques.

Why it matters

OpenAlex reports 219 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This paper proposes a hybrid methodology to improve the dynamic strength of frameworks by optimally locating and sizing the unified power flow controller (UPFC). The proposed method combines both the antlion optimiser (ALO) and invasive weed optimisation (IWO) techniques. The advantages of the proposed methodology are enhanced searching ability, better identification of optimal solutions and greater reliability. Initially, to locate UPFCs, using the ALO technique, the most extreme power loss bus is recognised as the optimal location. The capacity required to resolve the situation is determined by the IWO technique based on the minimum power loss, voltage deviation and establishment cost of the UPFCs. The proposed system is actualised and aims at the matrix laboratory (MATLAB) environment, while the power flow security and voltage stability are evaluated on the basis of the Institute of Electrical and Electronics Engineers (IEEE) standard benchmark system. At this point, voltage stability, power loss, overloading and UPFC costs are analysed through changing the system load and generation. The proposed working method is then assessed and compared with traditional techniques.

Key concepts: Upgrade, Unified power flow controller, Electric power system, Benchmark (surveying), Controller (irrigation), Control theory (sociology), MATLAB, Voltage

Related papers

Back to paper searchBrowse research topicsOriginal source
Ideal position and size selection of unified power flow controllers (UPFCs) to upgrade the dynamic stability of systems: An antlion optimiser and invasive weed optimisation Algorithm — Research Paper | ScholarLens