2020Archives of Hand and MicrosurgeryOpen access

Autogenous Inlay Bone Graft for Distal Humerus Nonunion with Metaphyseal Bone Defect: A Technical Note

Yong-Suk Lee, Dong Min Kim, Min-Sung Kang, Jong-Hwa Park, Sang-Uk Lee

Open full text 2 citations

Abstract

Distal humeral nonunion is one of the most concerned complications in elbow trauma. When bone loss at the fracture site is carried out due to nonunion, metaphyseal bone defect occurs. Therefore positioning of anatomical locking plate becomes difficult owing to abnormal bone contour, and fixation of small nonunion fragment is challenging. We introduce a good method of anatomical locking plate fixation with autogenous inlay strut bone graft for internal fixation. This technique is to insert autogenous inlay bone into the proximal medullary canal and hole of distal bone fragment which will lead to achieve correction of the anatomical alignment, length and rotation deformity. The inlay grafting is reduced to the shaft with two crossed K-wires temporarily. Definitive fixation is performed with locking plates, and autogenous bone graft is added at the defect site.

Open-access reader

About this research paper

What this paper is about

Distal humeral nonunion is one of the most concerned complications in elbow trauma. When bone loss at the fracture site is carried out due to nonunion, metaphyseal bone defect occurs. Therefore positioning of anatomical locking plate becomes difficult owing to abnormal bone contour, and fixation of small nonunion fragment is challenging. We introduce a good method of anatomical locking plate fixation with autogenous inlay strut bone graft for internal fixation. This technique is to insert autogenous inlay bone into the proximal medullary canal and hole of distal bone fragment which will lead to achieve correction of the anatomical alignment, length and rotation deformity. The inlay grafting is reduced to the shaft with two crossed K-wires temporarily. Definitive fixation is performed with locking plates, and autogenous bone graft is added at the defect site.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Distal humeral nonunion is one of the most concerned complications in elbow trauma. When bone loss at the fracture site is carried out due to nonunion, metaphyseal bone defect occurs. Therefore positioning of anatomical locking plate becomes difficult owing to abnormal bone contour, and fixation of small nonunion fragment is challenging. We introduce a good method of anatomical locking plate fixation with autogenous inlay strut bone graft for internal fixation. This technique is to insert autogenous inlay bone into the proximal medullary canal and hole of distal bone fragment which will lead to achieve correction of the anatomical alignment, length and rotation deformity. The inlay grafting is reduced to the shaft with two crossed K-wires temporarily. Definitive fixation is performed with locking plates, and autogenous bone graft is added at the defect site.

Key concepts: Inlay, Nonunion, Medicine, Fixation (population genetics), Medullary cavity, Bone grafting, Deformity, Humerus

Related papers

Back to paper searchBrowse research topicsOriginal source
Autogenous Inlay Bone Graft for Distal Humerus Nonunion with Metaphyseal Bone Defect: A Technical Note — Research Paper | ScholarLens