2020•Experimental Heat TransferRequires access

Experimental investigation on flow boiling heat transfer characteristics of R1234ze(E)/R152a in 6-mm ID horizontal smooth tube

Lele Wang, Yuande Dai, Jiahuan Wu, Biao Li

Open publisher page 13 citations

Abstract

The near-azeotropic refrigerant mixture R1234ze(E)/R152a (40/60 by mass%) was an excellent alternative refrigerant with outstanding environmental protection and thermophysical properties as well as good cycle performance. The flow boiling heat transfer characteristics of R1234ze(E)/R152a (40/60 by mass%) in horizontal smooth copper tube with inner diameter (ID) of 6 mm were investigated experimentally. The effects of mass flux (100–200 kg·m−2·s−1), saturation temperature (285.15–291.15 K), heat flux (5–20 kW·m−2), and vapor quality (0.02–0.98) on the boiling heat transfer coefficient (HTC) and critical vapor quality were analyzed. It was found that the boiling HTCs increased with increasing heat flux or saturation temperature, and decreased at first but then increased with rising mass flux. The boiling HTCs almost kept constant firstly but then decreased with increasing vapor quality. Besides, the critical vapor quality decreased with increasing heat flux or decreasing mass flux. Finally, the experimental results were compared with several correlations which predict boiling heat transfer characteristics, it could be concluded that the correlations proposed by Jung et al. and Choi et al., respectively, had high prediction accuracy.

About this research paper

What this paper is about

The near-azeotropic refrigerant mixture R1234ze(E)/R152a (40/60 by mass%) was an excellent alternative refrigerant with outstanding environmental protection and thermophysical properties as well as good cycle performance. The flow boiling heat transfer characteristics of R1234ze(E)/R152a (40/60 by mass%) in horizontal smooth copper tube with inner diameter (ID) of 6 mm were investigated experimentally. The effects of mass flux (100–200 kg·m−2·s−1), saturation temperature (285.15–291.15 K), heat flux (5–20 kW·m−2), and vapor quality (0.02–0.98) on the boiling heat transfer coefficient (HTC) and critical vapor quality were analyzed. It was found that the boiling HTCs increased with increasing heat flux or saturation temperature, and decreased at first but then increased with rising mass flux. The boiling HTCs almost kept constant firstly but then decreased with increasing vapor quality. Besides, the critical vapor quality decreased with increasing heat flux or decreasing mass flux. Finally, the experimental results were compared with several correlations which predict boiling heat transfer characteristics, it could be concluded that the correlations proposed by Jung et al. and Choi et al., respectively, had high prediction accuracy.

Why it matters

OpenAlex reports 13 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The near-azeotropic refrigerant mixture R1234ze(E)/R152a (40/60 by mass%) was an excellent alternative refrigerant with outstanding environmental protection and thermophysical properties as well as good cycle performance. The flow boiling heat transfer characteristics of R1234ze(E)/R152a (40/60 by mass%) in horizontal smooth copper tube with inner diameter (ID) of 6 mm were investigated experimentally. The effects of mass flux (100–200 kg·m−2·s−1), saturation temperature (285.15–291.15 K), heat flux (5–20 kW·m−2), and vapor quality (0.02–0.98) on the boiling heat transfer coefficient (HTC) and critical vapor quality were analyzed. It was found that the boiling HTCs increased with increasing heat flux or saturation temperature, and decreased at first but then increased with rising mass flux. The boiling HTCs almost kept constant firstly but then decreased with increasing vapor quality. Besides, the critical vapor quality decreased with increasing heat flux or decreasing mass flux. Finally, the experimental results were compared with several correlations which predict boiling heat transfer characteristics, it could be concluded that the correlations proposed by Jung et al. and Choi et al., respectively, had high prediction accuracy.

Key concepts: Materials science, Refrigerant, Vapor quality, Nucleate boiling, Thermodynamics, Heat flux, Boiling point, Heat transfer coefficient

Related papers

Back to paper searchBrowse research topicsOriginal source
Experimental investigation on flow boiling heat transfer characteristics of R1234ze(E)/R152a in 6-mm ID horizontal smooth tube — Research Paper | ScholarLens