2020•Applied SciencesOpen access

Application of Soundproofing Materials for Noise Reduction in Dental CAD/CAM Milling Machines

Eunsung Song, Young‐Jun Lim, Joongsoo Lee, Jung-Bon Moon, Bongju Kim

Open full text 9 citations

Abstract

Soundproofing materials are widely used in various fields as a passive measure to reduce noise. Despite this, there have been a few studies on the application of soundproofing materials on medical equipment, which is the main cause of noise in a medical environment. Despite the increasing number of studies on active noise control for the noise reduction of machines, it is difficult to apply customized noise control—i.e., specific control measures according to the various characteristics of that noise—due to its high cost and low effectiveness. Therefore, research on passive noise control using soundproofing materials is required for effective noise control. The 3D CAD/CAM milling machine, which is an essential device in the digitalized dental environment, is causing various problems as a new noise source. This study investigated the noise of the milling machine and considered its characteristics in application of an efficient soundproofing material for noise reduction. Additionally, a soundproofing material performance test was conducted to select an appropriate soundproofing material based on the noise characteristics of the milling machine. As milling machines cause noise issues in hospitals, the study results were analyzed in considering practical aspects for immediate application to actual sale products. This study suggests that the application of Thinsulator and a triple soundproofing mat (butyl 100% + aluminum + sound-insulating material) is effective in the noise reduction of milling machines.

Open-access reader

About this research paper

What this paper is about

Soundproofing materials are widely used in various fields as a passive measure to reduce noise. Despite this, there have been a few studies on the application of soundproofing materials on medical equipment, which is the main cause of noise in a medical environment. Despite the increasing number of studies on active noise control for the noise reduction of machines, it is difficult to apply customized noise control—i.e., specific control measures according to the various characteristics of that noise—due to its high cost and low effectiveness. Therefore, research on passive noise control using soundproofing materials is required for effective noise control. The 3D CAD/CAM milling machine, which is an essential device in the digitalized dental environment, is causing various problems as a new noise source. This study investigated the noise of the milling machine and considered its characteristics in application of an efficient soundproofing material for noise reduction. Additionally, a soundproofing material performance test was conducted to select an appropriate soundproofing material based on the noise characteristics of the milling machine. As milling machines cause noise issues in hospitals, the study results were analyzed in considering practical aspects for immediate application to actual sale products. This study suggests that the application of Thinsulator and a triple soundproofing mat (butyl 100% + aluminum + sound-insulating material) is effective in the noise reduction of milling machines.

Why it matters

OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Soundproofing materials are widely used in various fields as a passive measure to reduce noise. Despite this, there have been a few studies on the application of soundproofing materials on medical equipment, which is the main cause of noise in a medical environment. Despite the increasing number of studies on active noise control for the noise reduction of machines, it is difficult to apply customized noise control—i.e., specific control measures according to the various characteristics of that noise—due to its high cost and low effectiveness. Therefore, research on passive noise control using soundproofing materials is required for effective noise control. The 3D CAD/CAM milling machine, which is an essential device in the digitalized dental environment, is causing various problems as a new noise source. This study investigated the noise of the milling machine and considered its characteristics in application of an efficient soundproofing material for noise reduction. Additionally, a soundproofing material performance test was conducted to select an appropriate soundproofing material based on the noise characteristics of the milling machine. As milling machines cause noise issues in hospitals, the study results were analyzed in considering practical aspects for immediate application to actual sale products. This study suggests that the application of Thinsulator and a triple soundproofing mat (butyl 100% + aluminum + sound-insulating material) is effective in the noise reduction of milling machines.

Key concepts: Soundproofing, Noise control, Noise reduction, Noise (video), Engineering, Materials science, Acoustics, Computer science

Related papers

Back to paper searchBrowse research topicsOriginal source
Application of Soundproofing Materials for Noise Reduction in Dental CAD/CAM Milling Machines — Research Paper | ScholarLens