20202020 International Youth Conference on Radio Electronics, Electrical and Power Engineering (REEPE)Requires access

Fault Diagnosis of 3-phase Induction Machine Using Harmonic Content of Stator Current Spectrum

Muhammad Deeb, Nikolay F. Kotelenets

Open publisher page 8 citations

Abstract

Defects in operation of the induction motors changes the harmonic components of motor supply current. In this paper, Motor electrical current signature analysis (MCSA) is used to detect the inter- turn short circuits in only one winding of the motor stator. In this paper, a theoretical study was conducted to determine the harmonics resulting from the presence of inter- turn short circuits. An experimental module set of a 220V/380V-50Hz-11kW-4pole three- phase squirrel-cage induction machine has been used to verify the efficiency of this method. The experimental results proved the effectiveness of the proposed method in detecting inter-turn short circuit up to the failure of only two turn.

About this research paper

What this paper is about

Defects in operation of the induction motors changes the harmonic components of motor supply current. In this paper, Motor electrical current signature analysis (MCSA) is used to detect the inter- turn short circuits in only one winding of the motor stator. In this paper, a theoretical study was conducted to determine the harmonics resulting from the presence of inter- turn short circuits. An experimental module set of a 220V/380V-50Hz-11kW-4pole three- phase squirrel-cage induction machine has been used to verify the efficiency of this method. The experimental results proved the effectiveness of the proposed method in detecting inter-turn short circuit up to the failure of only two turn.

Why it matters

OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Defects in operation of the induction motors changes the harmonic components of motor supply current. In this paper, Motor electrical current signature analysis (MCSA) is used to detect the inter- turn short circuits in only one winding of the motor stator. In this paper, a theoretical study was conducted to determine the harmonics resulting from the presence of inter- turn short circuits. An experimental module set of a 220V/380V-50Hz-11kW-4pole three- phase squirrel-cage induction machine has been used to verify the efficiency of this method. The experimental results proved the effectiveness of the proposed method in detecting inter-turn short circuit up to the failure of only two turn.

Key concepts: Stator, Harmonics, Induction motor, Harmonic, Harmonic analysis, Signature (topology), Current (fluid), Electronic circuit

Related papers

Back to paper searchBrowse research topicsOriginal source
Fault Diagnosis of 3-phase Induction Machine Using Harmonic Content of Stator Current Spectrum — Research Paper | ScholarLens