2020Acta Obstetricia Et Gynecologica ScandinavicaOpen access

Quantitative fetal fibronectin for prediction of preterm birth in asymptomatic twin pregnancy

Katy Kuhrt, Natasha Hezelgrave‐Elliott, Sarah J. Stock, Rachel M. Tribe, Paul T. Seed, Andrew Shennan

Open full text 17 citations

Abstract

Abstract Introduction To evaluate cervicovaginal fluid quantitative fetal fibronectin, measured by a bedside analyzer, to predict spontaneous preterm birth in twin pregnancy before 30 weeks of gestation. Material and methods In a prospective cohort study, we studied the accuracy of quantitative fetal fibronectin measured between 18 and 27+6 weeks of gestation in high‐risk asymptomatic women with twin pregnancies, to predict spontaneous preterm birth before 30 weeks of gestation. Predefined fetal fibronectin thresholds were ≥10, ≥50 and ≥200 ng/mL. Predictive statistics were also calculated to evaluate accuracy of “early” tests, performed between 18 and 21+6 weeks and “standard” tests performed between 22+0 and 27+6 weeks of gestation in the same cohort. Subgroup analysis was performed according to cervical length measurement. In addition, we compared accuracy of prediction with quantitative fetal fibronectin measured during the standard test period in asymptomatic twin pregnancy with no additional risk factors, to twin pregnancies with one or more additional risk factors for spontaneous preterm birth. Results Of 130 eligible women identified with quantitative fetal fibronectin tests undertaken during the standard testing period, 9% delivered before 30 weeks of gestation. Quantitative fetal fibronectin was significantly related to outcome before 30/40 (ROC curves of 0.8 [95% CI 0.7‐1]). Early tests were not significantly predictive; ROC area 0.53 (95% CI 0.29‐0.81). There was a trend towards better predictive accuracy when one or more additional risk factors for spontaneous preterm birth or cervical length were considered. Conclusions Quantitative fetal fibronectin measured from 22 to 27+6 weeks of gestation accurately predicts spontaneous preterm birth at <30 weeks of gestation. Tests undertaken earlier are of limited value. Consideration of cervical length or prior history in addition to quantitative fetal fibronectin strengthens prediction.

Open-access reader

About this research paper

What this paper is about

Abstract Introduction To evaluate cervicovaginal fluid quantitative fetal fibronectin, measured by a bedside analyzer, to predict spontaneous preterm birth in twin pregnancy before 30 weeks of gestation. Material and methods In a prospective cohort study, we studied the accuracy of quantitative fetal fibronectin measured between 18 and 27+6 weeks of gestation in high‐risk asymptomatic women with twin pregnancies, to predict spontaneous preterm birth before 30 weeks of gestation. Predefined fetal fibronectin thresholds were ≥10, ≥50 and ≥200 ng/mL. Predictive statistics were also calculated to evaluate accuracy of “early” tests, performed between 18 and 21+6 weeks and “standard” tests performed between 22+0 and 27+6 weeks of gestation in the same cohort. Subgroup analysis was performed according to cervical length measurement. In addition, we compared accuracy of prediction with quantitative fetal fibronectin measured during the standard test period in asymptomatic twin pregnancy with no additional risk factors, to twin pregnancies with one or more additional risk factors for spontaneous preterm birth. Results Of 130 eligible women identified with quantitative fetal fibronectin tests undertaken during the standard testing period, 9% delivered before 30 weeks of gestation. Quantitative fetal fibronectin was significantly related to outcome before 30/40 (ROC curves of 0.8 [95% CI 0.7‐1]). Early tests were not significantly predictive; ROC area 0.53 (95% CI 0.29‐0.81). There was a trend towards better predictive accuracy when one or more additional risk factors for spontaneous preterm birth or cervical length were considered. Conclusions Quantitative fetal fibronectin measured from 22 to 27+6 weeks of gestation accurately predicts spontaneous preterm birth at <30 weeks of gestation. Tests undertaken earlier are of limited value. Consideration of cervical length or prior history in addition to quantitative fetal fibronectin strengthens prediction.

Why it matters

OpenAlex reports 17 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract Introduction To evaluate cervicovaginal fluid quantitative fetal fibronectin, measured by a bedside analyzer, to predict spontaneous preterm birth in twin pregnancy before 30 weeks of gestation. Material and methods In a prospective cohort study, we studied the accuracy of quantitative fetal fibronectin measured between 18 and 27+6 weeks of gestation in high‐risk asymptomatic women with twin pregnancies, to predict spontaneous preterm birth before 30 weeks of gestation. Predefined fetal fibronectin thresholds were ≥10, ≥50 and ≥200 ng/mL. Predictive statistics were also calculated to evaluate accuracy of “early” tests, performed between 18 and 21+6 weeks and “standard” tests performed between 22+0 and 27+6 weeks of gestation in the same cohort. Subgroup analysis was performed according to cervical length measurement. In addition, we compared accuracy of prediction with quantitative fetal fibronectin measured during the standard test period in asymptomatic twin pregnancy with no additional risk factors, to twin pregnancies with one or more additional risk factors for spontaneous preterm birth. Results Of 130 eligible women identified with quantitative fetal fibronectin tests undertaken during the standard testing period, 9% delivered before 30 weeks of gestation. Quantitative fetal fibronectin was significantly related to outcome before 30/40 (ROC curves of 0.8 [95% CI 0.7‐1]). Early tests were not significantly predictive; ROC area 0.53 (95% CI 0.29‐0.81). There was a trend towards better predictive accuracy when one or more additional risk factors for spontaneous preterm birth or cervical length were considered. Conclusions Quantitative fetal fibronectin measured from 22 to 27+6 weeks of gestation accurately predicts spontaneous preterm birth at <30 weeks of gestation. Tests undertaken earlier are of limited value. Consideration of cervical length or prior history in addition to quantitative fetal fibronectin strengthens prediction.

Key concepts: Fetal fibronectin, Medicine, Gestation, Asymptomatic, Obstetrics, Pregnancy, Prospective cohort study, Fetus

Related papers

Back to paper searchBrowse research topicsOriginal source
Quantitative fetal fibronectin for prediction of preterm birth in asymptomatic twin pregnancy — Research Paper | ScholarLens