2020Folia MedicaOpen access

Peak Responses during Exercise Treadmill Testing using Individualized Ramp Protocol and Modified Bruce Protocol in Elderly Patients

Sergey Kozlov, Martin Čaprnda, О. В. Чернова, М. А. Матвеева, И. А. Алексеева, Katarína Gazdíková, Ľudovít Gašpar, Peter Kružliak, Slavomíra Filipová, Zufar Gabbasov

Open full text 9 citations

Abstract

BACKGROUND: Exercise capacity is well known to be an important prognostic factor in patients with cardiovascular disease and among healthy persons. AIM: To determine if there are any differences between the peak exercise response during exercise treadmill testing with the individualized ramp protocol and the modified Bruce protocol in elderly patients. MATERIALS AND METHODS: The study included 40 patients (both male and female), aged 70 years and older, who had not had a baseline history of the confirmed coronary artery disease or heart failure diagnoses. All patients underwent exercise treadmill testing using modified Bruce protocol and individualized ramp protocol for 2 consecutive days. Peak heart rate, peak systolic and diastolic blood pressure, peak pressure-rate double product, exercise duration, and peak metabolic equivalents were recorded in both tests. Perceived level of exertion was evaluated using the Borg 10-point scale. RESULTS: The average duration of exercise was longer for the ramp protocol than for the modified Bruce protocol. When the modified Bruce protocol was used, patients achieved a lower workload than they did in using the ramp protocol. The rating of perceived exertion using the revised Borg scale (0 to 10) was 5.6±1.4 for the ramp protocol and 8.7±1.4 for the modified Bruce protocol, which indicates that the patients found the ramp protocol easier. CONCLUSION: In elderly patients the individualized ramp treadmill protocol allows to achieve the optimal test duration with higher degrees of workload and greater patient comfort during the test more often than does the modified Bruce protocol.

Open-access reader

About this research paper

What this paper is about

BACKGROUND: Exercise capacity is well known to be an important prognostic factor in patients with cardiovascular disease and among healthy persons. AIM: To determine if there are any differences between the peak exercise response during exercise treadmill testing with the individualized ramp protocol and the modified Bruce protocol in elderly patients. MATERIALS AND METHODS: The study included 40 patients (both male and female), aged 70 years and older, who had not had a baseline history of the confirmed coronary artery disease or heart failure diagnoses. All patients underwent exercise treadmill testing using modified Bruce protocol and individualized ramp protocol for 2 consecutive days. Peak heart rate, peak systolic and diastolic blood pressure, peak pressure-rate double product, exercise duration, and peak metabolic equivalents were recorded in both tests. Perceived level of exertion was evaluated using the Borg 10-point scale. RESULTS: The average duration of exercise was longer for the ramp protocol than for the modified Bruce protocol. When the modified Bruce protocol was used, patients achieved a lower workload than they did in using the ramp protocol. The rating of perceived exertion using the revised Borg scale (0 to 10) was 5.6±1.4 for the ramp protocol and 8.7±1.4 for the modified Bruce protocol, which indicates that the patients found the ramp protocol easier. CONCLUSION: In elderly patients the individualized ramp treadmill protocol allows to achieve the optimal test duration with higher degrees of workload and greater patient comfort during the test more often than does the modified Bruce protocol.

Why it matters

OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Exercise capacity is well known to be an important prognostic factor in patients with cardiovascular disease and among healthy persons. AIM: To determine if there are any differences between the peak exercise response during exercise treadmill testing with the individualized ramp protocol and the modified Bruce protocol in elderly patients. MATERIALS AND METHODS: The study included 40 patients (both male and female), aged 70 years and older, who had not had a baseline history of the confirmed coronary artery disease or heart failure diagnoses. All patients underwent exercise treadmill testing using modified Bruce protocol and individualized ramp protocol for 2 consecutive days. Peak heart rate, peak systolic and diastolic blood pressure, peak pressure-rate double product, exercise duration, and peak metabolic equivalents were recorded in both tests. Perceived level of exertion was evaluated using the Borg 10-point scale. RESULTS: The average duration of exercise was longer for the ramp protocol than for the modified Bruce protocol. When the modified Bruce protocol was used, patients achieved a lower workload than they did in using the ramp protocol. The rating of perceived exertion using the revised Borg scale (0 to 10) was 5.6±1.4 for the ramp protocol and 8.7±1.4 for the modified Bruce protocol, which indicates that the patients found the ramp protocol easier. CONCLUSION: In elderly patients the individualized ramp treadmill protocol allows to achieve the optimal test duration with higher degrees of workload and greater patient comfort during the test more often than does the modified Bruce protocol.

Key concepts: Bruce protocol, Rating of perceived exertion, Medicine, Heart rate, Treadmill, Metabolic equivalent, Protocol (science), Workload

Related papers

Back to paper searchBrowse research topicsOriginal source
Peak Responses during Exercise Treadmill Testing using Individualized Ramp Protocol and Modified Bruce Protocol in Elderly Patients — Research Paper | ScholarLens