2019•QUT ePrints (Queensland University of Technology)Open access

Load-bearing walls made of cold-formed steel hollow section studs exposed to fire

Yunxiang Tao, Mahen Mahendran, Anthony Deloge Ariyanayagam

Open full text 5 citations

Abstract

Light gauge steel frame (LSF) walls are used as primary load-bearing components in cold -formed steel (CFS) buildings. With the use of CFS structures in the construction of mid-rise buildings, fire safety of LSF walls has become a more critical issue for designers. This research project has investigated the fire performance of LSF walls made of cold-formed square hollows section (SHS) studs.A full-scale fire test was first conducted under standard fire conditions, and finite element (FE) models were then developed and validated. This paper presents the details of the fire test and FE modelling of SHS stud wall in fire and the results. Detailed comparisons between the results from the fire test and FE modelling, such as time-temperature profiles of SHS studs and plasterboards, fire resistance level of the LSF wall, stud failure mode and deflections, are also presented in the paper.

Open-access reader

About this research paper

What this paper is about

Light gauge steel frame (LSF) walls are used as primary load-bearing components in cold -formed steel (CFS) buildings. With the use of CFS structures in the construction of mid-rise buildings, fire safety of LSF walls has become a more critical issue for designers. This research project has investigated the fire performance of LSF walls made of cold-formed square hollows section (SHS) studs.A full-scale fire test was first conducted under standard fire conditions, and finite element (FE) models were then developed and validated. This paper presents the details of the fire test and FE modelling of SHS stud wall in fire and the results. Detailed comparisons between the results from the fire test and FE modelling, such as time-temperature profiles of SHS studs and plasterboards, fire resistance level of the LSF wall, stud failure mode and deflections, are also presented in the paper.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Light gauge steel frame (LSF) walls are used as primary load-bearing components in cold -formed steel (CFS) buildings. With the use of CFS structures in the construction of mid-rise buildings, fire safety of LSF walls has become a more critical issue for designers. This research project has investigated the fire performance of LSF walls made of cold-formed square hollows section (SHS) studs.A full-scale fire test was first conducted under standard fire conditions, and finite element (FE) models were then developed and validated. This paper presents the details of the fire test and FE modelling of SHS stud wall in fire and the results. Detailed comparisons between the results from the fire test and FE modelling, such as time-temperature profiles of SHS studs and plasterboards, fire resistance level of the LSF wall, stud failure mode and deflections, are also presented in the paper.

Key concepts: Fire test, Fire resistance, Structural engineering, Cold-formed steel, Fire performance, Load bearing, Engineering, Full scale

Related papers

Back to paper searchBrowse research topicsOriginal source
Load-bearing walls made of cold-formed steel hollow section studs exposed to fire — Research Paper | ScholarLens