2020IOP Conference Series Earth and Environmental ScienceOpen access

Study on the calibration method for tri-axis fluxgate gradiometer

Chaoqun Xu, Kui Huang, Shaohua Zhang, Lifei Meng

Open full text 5 citations

Abstract

Abstract Aiming at the measurement errors caused by non-orthogonality, inconsistent sensitivity, zero-offset of the tri-axis fluxgate sensor and the position misalignment of two fluxgate sensors composed of the gradiometer, this paper establishes the correction model of measurement error of magnetometer and gradiometer, puts forward the comprehensive coefficient method, and uses the non-magnetic turntable to calibrate the Mag648 three-axis magnetometer and gradiometer in the uniform magnetic environment. The experimental results show that the method can reduce the maximum total magnetic field deviation of the two magnetometers from 552.4 nT to 15.0 nT, and reduce the maximum output deviation of the three-component gradiometer from 3891.5 nT to 37.2 nT, which effectively improves the reliability of the three-axis magnetic sensor in measurement.

Open-access reader

About this research paper

What this paper is about

Abstract Aiming at the measurement errors caused by non-orthogonality, inconsistent sensitivity, zero-offset of the tri-axis fluxgate sensor and the position misalignment of two fluxgate sensors composed of the gradiometer, this paper establishes the correction model of measurement error of magnetometer and gradiometer, puts forward the comprehensive coefficient method, and uses the non-magnetic turntable to calibrate the Mag648 three-axis magnetometer and gradiometer in the uniform magnetic environment. The experimental results show that the method can reduce the maximum total magnetic field deviation of the two magnetometers from 552.4 nT to 15.0 nT, and reduce the maximum output deviation of the three-component gradiometer from 3891.5 nT to 37.2 nT, which effectively improves the reliability of the three-axis magnetic sensor in measurement.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract Aiming at the measurement errors caused by non-orthogonality, inconsistent sensitivity, zero-offset of the tri-axis fluxgate sensor and the position misalignment of two fluxgate sensors composed of the gradiometer, this paper establishes the correction model of measurement error of magnetometer and gradiometer, puts forward the comprehensive coefficient method, and uses the non-magnetic turntable to calibrate the Mag648 three-axis magnetometer and gradiometer in the uniform magnetic environment. The experimental results show that the method can reduce the maximum total magnetic field deviation of the two magnetometers from 552.4 nT to 15.0 nT, and reduce the maximum output deviation of the three-component gradiometer from 3891.5 nT to 37.2 nT, which effectively improves the reliability of the three-axis magnetic sensor in measurement.

Key concepts: Gradiometer, Fluxgate compass, Magnetometer, Offset (computer science), Calibration, Physics, Sensitivity (control systems), Accelerometer

Related papers

Back to paper searchBrowse research topicsOriginal source
Study on the calibration method for tri-axis fluxgate gradiometer — Research Paper | ScholarLens