Study on Seismic Performance of Long-Span Railway Continuous Girder Bridges in High Seismic Intensity Region
Wei Lu, Ziqi Li, Lusong Yu, Jianning Li
Abstract
Wei Lu, Ziqi Li, Lusong Yu, Jianning Li
Abstract
In order to study the seismic response characteristics of long-span railway continuous girder bridges, located in the high seismic intensity regions. Take reasonable measures, to solve the seismic problem of fixed piers. This paper introducing a long-span railway continuous girder bridge as a research background, establishes a finite element model, nonlinear seismic response analysis of the whole bridge was carried, using the ductile seismic design method and the seismic isolation method. The parameters of the liquid viscous damper, and its influence on the damping effect are discussed. The results show that when using the ductility seismic design method, the structure relies on the plastic hinge hysteresis mechanism to dissipate the seismic energy, which may causes the large damage of the fixed pier. After damping design, the seismic design difficulty has been reduced. But to further solve the seismic problem, it is recommended that other seismic isolation devices be used simultaneously.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
In order to study the seismic response characteristics of long-span railway continuous girder bridges, located in the high seismic intensity regions. Take reasonable measures, to solve the seismic problem of fixed piers. This paper introducing a long-span railway continuous girder bridge as a research background, establishes a finite element model, nonlinear seismic response analysis of the whole bridge was carried, using the ductile seismic design method and the seismic isolation method. The parameters of the liquid viscous damper, and its influence on the damping effect are discussed. The results show that when using the ductility seismic design method, the structure relies on the plastic hinge hysteresis mechanism to dissipate the seismic energy, which may causes the large damage of the fixed pier. After damping design, the seismic design difficulty has been reduced. But to further solve the seismic problem, it is recommended that other seismic isolation devices be used simultaneously.
Key concepts: Structural engineering, Seismic analysis, Pier, Girder, Incremental Dynamic Analysis, Bridge (graph theory), Seismic loading, Damper