A 10 years retrospective study of assessment of prevalence and risk factors of dental implants failures
Anuj Singh Parihar, Rohit Singh, Vikas Vaibhav, Kunal Kumar, Revati Singh, Jeethu John Jerry
Abstract
Anuj Singh Parihar, Rohit Singh, Vikas Vaibhav, Kunal Kumar, Revati Singh, Jeethu John Jerry
Abstract
Aim: The present study was conducted to determine the prevalence rate of dental implants failure and risk factors affecting dental implant outcome. Materials and Methods: The present retrospective study was conducted on 826 patients who received 1420 dental implants in both genders. Length of implant, diameter of implant, location of implant, and bone quality were recorded. Risk factors such as habit of smoking, history of diabetes, hypertension, etc., were recorded. Results: In 516 males, 832 dental implants and in 310 females, 588 dental implants were placed. Maximum dental implant failure was seen with length <10 mm (16%), with diameter <3.75 mm, and with type IV bone (20.6%). The difference found to be significant (P < 0.05). Maximum dental implant failures were seen with smoking (37%) followed by hypertension (20.8%), diabetes (20.3%), and CVDs (18.7%). Healthy patients had the lowest failure rate (4.37%). Conclusion: Dental implant failure was high in type IV bone, dental implant with <3.75 mm diameter, dental implant with length <10.0 mm, and among smokers.
OpenAlex reports 34 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Aim: The present study was conducted to determine the prevalence rate of dental implants failure and risk factors affecting dental implant outcome. Materials and Methods: The present retrospective study was conducted on 826 patients who received 1420 dental implants in both genders. Length of implant, diameter of implant, location of implant, and bone quality were recorded. Risk factors such as habit of smoking, history of diabetes, hypertension, etc., were recorded. Results: In 516 males, 832 dental implants and in 310 females, 588 dental implants were placed. Maximum dental implant failure was seen with length <10 mm (16%), with diameter <3.75 mm, and with type IV bone (20.6%). The difference found to be significant (P < 0.05). Maximum dental implant failures were seen with smoking (37%) followed by hypertension (20.8%), diabetes (20.3%), and CVDs (18.7%). Healthy patients had the lowest failure rate (4.37%). Conclusion: Dental implant failure was high in type IV bone, dental implant with <3.75 mm diameter, dental implant with length <10.0 mm, and among smokers.
Key concepts: Medicine, Implant, Dentistry, Dental implant, Implant failure, Retrospective cohort study, Surgery