2020European Archives of Oto-Rhino-LaryngologyOpen access

Comparison of microscopic and endoscopic views in cadaveric ears

John J. Guy, Jameel Muzaffar, Chris Coulson

Open full text 12 citations

Abstract

PURPOSE: The advent of endoscopic otosurgery provides reduced tissue destruction with theoretically improved views, yet a quantification of the difference of exposure between microscopic and endoscopic approaches has not yet been performed in human specimens. The objective of this study was to assess the difference in views of cadaveric tympanic membranes when inspected with operating microscopes or endoscopes. METHODS: A circular graduated disc was inserted into eight cadaveric external ear canals to rest against the tympanic membrane. Three independent observers assessed the maximum possible observable radius of the graduated disc in each ear using a 0° endoscope and a surgical microscope in superior, inferior, posterior, and anterior directions. RESULTS: The endoscope was able to view a significantly larger mean maximum visible radius than the microscope in posterior, superior, anterior, and inferior directions. This represented a mean gain in observable distance of 19.18%. There was a smaller variation in mean maximum visible radius than the microscope. CONCLUSION: The wider field of view in an endoscope compared to a microscope implies reduced surgical tissue damage is needed to provide sufficient operative exposure. Enhanced views of the attic were demonstrated by the endoscope, further indicating utility in cholesteatoma observation and surgery.

Open-access reader

About this research paper

What this paper is about

PURPOSE: The advent of endoscopic otosurgery provides reduced tissue destruction with theoretically improved views, yet a quantification of the difference of exposure between microscopic and endoscopic approaches has not yet been performed in human specimens. The objective of this study was to assess the difference in views of cadaveric tympanic membranes when inspected with operating microscopes or endoscopes. METHODS: A circular graduated disc was inserted into eight cadaveric external ear canals to rest against the tympanic membrane. Three independent observers assessed the maximum possible observable radius of the graduated disc in each ear using a 0° endoscope and a surgical microscope in superior, inferior, posterior, and anterior directions. RESULTS: The endoscope was able to view a significantly larger mean maximum visible radius than the microscope in posterior, superior, anterior, and inferior directions. This represented a mean gain in observable distance of 19.18%. There was a smaller variation in mean maximum visible radius than the microscope. CONCLUSION: The wider field of view in an endoscope compared to a microscope implies reduced surgical tissue damage is needed to provide sufficient operative exposure. Enhanced views of the attic were demonstrated by the endoscope, further indicating utility in cholesteatoma observation and surgery.

Why it matters

OpenAlex reports 12 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: The advent of endoscopic otosurgery provides reduced tissue destruction with theoretically improved views, yet a quantification of the difference of exposure between microscopic and endoscopic approaches has not yet been performed in human specimens. The objective of this study was to assess the difference in views of cadaveric tympanic membranes when inspected with operating microscopes or endoscopes. METHODS: A circular graduated disc was inserted into eight cadaveric external ear canals to rest against the tympanic membrane. Three independent observers assessed the maximum possible observable radius of the graduated disc in each ear using a 0° endoscope and a surgical microscope in superior, inferior, posterior, and anterior directions. RESULTS: The endoscope was able to view a significantly larger mean maximum visible radius than the microscope in posterior, superior, anterior, and inferior directions. This represented a mean gain in observable distance of 19.18%. There was a smaller variation in mean maximum visible radius than the microscope. CONCLUSION: The wider field of view in an endoscope compared to a microscope implies reduced surgical tissue damage is needed to provide sufficient operative exposure. Enhanced views of the attic were demonstrated by the endoscope, further indicating utility in cholesteatoma observation and surgery.

Key concepts: Cadaveric spasm, Endoscope, Microscope, Operating microscope, Endoscopy, RADIUS, Cholesteatoma, Anatomy

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison of microscopic and endoscopic views in cadaveric ears — Research Paper | ScholarLens