2020Geophysical Research LettersOpen access

High‐Accuracy Near‐Infrared Carbon Dioxide Intensity Measurements to Support Remote Sensing

David A. Long, Zachary Reed, Adam J. Fleisher, Joseph Mendonca, Sébastien Roche, Joseph Hodges

Open full text 37 citations

Abstract

Abstract Two cavity ring‐down spectrometers were employed to accurately measure line intensities in a series of near‐infrared carbon dioxide bands including (30012) ← (00001), (30013) ← (00001), and (30014) ← (00001) near 1.6 μm. Relative combined standard uncertainties for these band intensities were less than 0.1% and showed significant, percent‐level deviations with respect to many existing spectroscopic databases (although close agreement was observed with the HITRAN 2016 database in the (30013) ← (00001) and (30014) ← (00001) bands). Further, the resulting line intensities were utilized in Total Carbon Column Observing Network retrievals and led to significantly reduced biases in the (30012) ← (00001) and (30013) ← (00001) bands. These results indicate that refinements of spectroscopic databases are required to meet the accuracy targets of both ground‐ and satellite‐based remote sensing missions.

Open-access reader

About this research paper

What this paper is about

Abstract Two cavity ring‐down spectrometers were employed to accurately measure line intensities in a series of near‐infrared carbon dioxide bands including (30012) ← (00001), (30013) ← (00001), and (30014) ← (00001) near 1.6 μm. Relative combined standard uncertainties for these band intensities were less than 0.1% and showed significant, percent‐level deviations with respect to many existing spectroscopic databases (although close agreement was observed with the HITRAN 2016 database in the (30013) ← (00001) and (30014) ← (00001) bands). Further, the resulting line intensities were utilized in Total Carbon Column Observing Network retrievals and led to significantly reduced biases in the (30012) ← (00001) and (30013) ← (00001) bands. These results indicate that refinements of spectroscopic databases are required to meet the accuracy targets of both ground‐ and satellite‐based remote sensing missions.

Why it matters

OpenAlex reports 37 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract Two cavity ring‐down spectrometers were employed to accurately measure line intensities in a series of near‐infrared carbon dioxide bands including (30012) ← (00001), (30013) ← (00001), and (30014) ← (00001) near 1.6 μm. Relative combined standard uncertainties for these band intensities were less than 0.1% and showed significant, percent‐level deviations with respect to many existing spectroscopic databases (although close agreement was observed with the HITRAN 2016 database in the (30013) ← (00001) and (30014) ← (00001) bands). Further, the resulting line intensities were utilized in Total Carbon Column Observing Network retrievals and led to significantly reduced biases in the (30012) ← (00001) and (30013) ← (00001) bands. These results indicate that refinements of spectroscopic databases are required to meet the accuracy targets of both ground‐ and satellite‐based remote sensing missions.

Key concepts: HITRAN, Remote sensing, Near-infrared spectroscopy, Spectrometer, Carbon dioxide, Satellite, Infrared, Environmental science

Related papers

Back to paper searchBrowse research topicsOriginal source
High‐Accuracy Near‐Infrared Carbon Dioxide Intensity Measurements to Support Remote Sensing — Research Paper | ScholarLens