Comparison Between the eyeWatch Device and the Ahmed Valve in Refractory Glaucoma
Sylvain Roy, Adan Villamarin, Constantinos Stergiopulos, Stéphane Bigler, Nikolaos Stergiopulos, Josephine Wachtl, André Mermoud, Christoph Kniestedt
Abstract
Sylvain Roy, Adan Villamarin, Constantinos Stergiopulos, Stéphane Bigler, Nikolaos Stergiopulos, Josephine Wachtl, André Mermoud, Christoph Kniestedt
Abstract
PURPOSE: To assess the efficacy and safety of a glaucoma procedure to control intraocular pressure (IOP) using the adjustable eyeWatch glaucoma drainage device compared with Ahmed glaucoma valve (AGV) in refractory glaucoma. PATIENTS AND METHODS: Monocentric, retrospective, comparative clinical trial. Patients suffering from refractory glaucoma after failed surgeries and requiring a further glaucoma procedure including an aqueous shunt were enrolled in this study. The first group AGV included patients with an AGV. The second group eW-B included patients receiving an eyeWatch used in connection with a Baerveldt glaucoma implant. The primary outcome was the success rate, defined as an IOP≤16 mm Hg and reduction of >20% from baseline, and IOP≥5 mm Hg. Secondary outcomes were mean IOP, number of antiglaucoma medications, visual acuity, number and type of complications. RESULTS: Twenty-one patients were included. The mean follow-up time was 13.2±3.4 months. Mean IOP decreased from 24.8±9.0 mm Hg before surgery to 13.8±3.6 mm Hg at 12 months for group AGV, and 27.3±7.0 to 12.8±2.4 mm Hg for group eW-B, respectively (P<0.05). Mean number of glaucoma medications decreased from 3.0±0.7 before surgery to 0.3±0.7 at last control for group AGV, and 2.9±0.8 before surgery to 0.2±0.4 for group eW-B, respectively (P<0.05). The complete and overall success rates were 50% and 58% for group AGV, and 67% and 89% for group eW-B, respectively. CONCLUSIONS: The postoperative adjustability of the eyeWatch is believed to help with getting fewer complications and better IOP management whereas AGV cannot be adjusted postoperatively.
OpenAlex reports 16 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
PURPOSE: To assess the efficacy and safety of a glaucoma procedure to control intraocular pressure (IOP) using the adjustable eyeWatch glaucoma drainage device compared with Ahmed glaucoma valve (AGV) in refractory glaucoma. PATIENTS AND METHODS: Monocentric, retrospective, comparative clinical trial. Patients suffering from refractory glaucoma after failed surgeries and requiring a further glaucoma procedure including an aqueous shunt were enrolled in this study. The first group AGV included patients with an AGV. The second group eW-B included patients receiving an eyeWatch used in connection with a Baerveldt glaucoma implant. The primary outcome was the success rate, defined as an IOP≤16 mm Hg and reduction of >20% from baseline, and IOP≥5 mm Hg. Secondary outcomes were mean IOP, number of antiglaucoma medications, visual acuity, number and type of complications. RESULTS: Twenty-one patients were included. The mean follow-up time was 13.2±3.4 months. Mean IOP decreased from 24.8±9.0 mm Hg before surgery to 13.8±3.6 mm Hg at 12 months for group AGV, and 27.3±7.0 to 12.8±2.4 mm Hg for group eW-B, respectively (P<0.05). Mean number of glaucoma medications decreased from 3.0±0.7 before surgery to 0.3±0.7 at last control for group AGV, and 2.9±0.8 before surgery to 0.2±0.4 for group eW-B, respectively (P<0.05). The complete and overall success rates were 50% and 58% for group AGV, and 67% and 89% for group eW-B, respectively. CONCLUSIONS: The postoperative adjustability of the eyeWatch is believed to help with getting fewer complications and better IOP management whereas AGV cannot be adjusted postoperatively.
Key concepts: Glaucoma valve, Medicine, Glaucoma, Intraocular pressure, Refractory (planetary science), Ophthalmology, Glaucoma surgery, Visual acuity