2020•Energy StorageRequires access

A simple method for the design of thermal energy storage systems

Álvaro Campos‐Celador, Gonzalo Diarce, Pello Larrinaga, Ana García-Romero

Open publisher page 17 citations

Abstract

Abstract One of the key factors that currently limits the commercial deployment of thermal energy storage (TES) systems is their complex design procedure, especially in the case of latent heat TES systems. Design procedures should address both the specificities of the TES system under consideration and those of the application to be integrated within. This article presents a fast and easy to apply methodology for the selection of the design of TES systems suitable for both direct and indirect contact sensible and latent TES. The methodology is divided into four steps covering: (a) description of the thermal process or application, (b) definition of the specifications to be met by the TES system, (c) characterization of the specific TES system under consideration and (d) the determination of the TES design. This methodology needs as major inputs the operation conditions of the energy system where the TES system will be integrated, that is, temperatures and mass‐flow; as well as the charging and discharging time performed by the TES system under different conditions. The latter can be generally deduced from the Fourier number, which can be obtained both theoretically (ie, by simulation) or empirically from the analysis of the TES technology under consideration. The methodology is then applied to a 10 kW residential cogeneration application considering two TES technologies. One consists of a direct‐contact hot water storage tank and the other, of an indirect‐contact plate‐based latent heat TES system developed by the authors. The resulting volume needs for the hot water storage tank is approximately twice the volume of the latent heat TES system, respectively, 5.97 and 2.96 m3. The presented methodology eases the design process of TES systems and decreases the amount of time needed to size them from days/hours to minutes.

About this research paper

What this paper is about

Abstract One of the key factors that currently limits the commercial deployment of thermal energy storage (TES) systems is their complex design procedure, especially in the case of latent heat TES systems. Design procedures should address both the specificities of the TES system under consideration and those of the application to be integrated within. This article presents a fast and easy to apply methodology for the selection of the design of TES systems suitable for both direct and indirect contact sensible and latent TES. The methodology is divided into four steps covering: (a) description of the thermal process or application, (b) definition of the specifications to be met by the TES system, (c) characterization of the specific TES system under consideration and (d) the determination of the TES design. This methodology needs as major inputs the operation conditions of the energy system where the TES system will be integrated, that is, temperatures and mass‐flow; as well as the charging and discharging time performed by the TES system under different conditions. The latter can be generally deduced from the Fourier number, which can be obtained both theoretically (ie, by simulation) or empirically from the analysis of the TES technology under consideration. The methodology is then applied to a 10 kW residential cogeneration application considering two TES technologies. One consists of a direct‐contact hot water storage tank and the other, of an indirect‐contact plate‐based latent heat TES system developed by the authors. The resulting volume needs for the hot water storage tank is approximately twice the volume of the latent heat TES system, respectively, 5.97 and 2.96 m3. The presented methodology eases the design process of TES systems and decreases the amount of time needed to size them from days/hours to minutes.

Why it matters

OpenAlex reports 17 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract One of the key factors that currently limits the commercial deployment of thermal energy storage (TES) systems is their complex design procedure, especially in the case of latent heat TES systems. Design procedures should address both the specificities of the TES system under consideration and those of the application to be integrated within. This article presents a fast and easy to apply methodology for the selection of the design of TES systems suitable for both direct and indirect contact sensible and latent TES. The methodology is divided into four steps covering: (a) description of the thermal process or application, (b) definition of the specifications to be met by the TES system, (c) characterization of the specific TES system under consideration and (d) the determination of the TES design. This methodology needs as major inputs the operation conditions of the energy system where the TES system will be integrated, that is, temperatures and mass‐flow; as well as the charging and discharging time performed by the TES system under different conditions. The latter can be generally deduced from the Fourier number, which can be obtained both theoretically (ie, by simulation) or empirically from the analysis of the TES technology under consideration. The methodology is then applied to a 10 kW residential cogeneration application considering two TES technologies. One consists of a direct‐contact hot water storage tank and the other, of an indirect‐contact plate‐based latent heat TES system developed by the authors. The resulting volume needs for the hot water storage tank is approximately twice the volume of the latent heat TES system, respectively, 5.97 and 2.96 m3. The presented methodology eases the design process of TES systems and decreases the amount of time needed to size them from days/hours to minutes.

Key concepts: Thermal energy storage, Process engineering, Thermal mass, Process (computing), Computer data storage, Systems design, Computer science, Latent heat

Related papers

Back to paper searchBrowse research topicsOriginal source
A simple method for the design of thermal energy storage systems — Research Paper | ScholarLens