2020•Journal of the American Heart AssociationOpen access

Electrophysiology Testing to Stratify Patients With Left Bundle Branch Block After Transcatheter Aortic Valve Implantation

Sven Knecht, Beat Andreas Schaer, Tobias Reichlin, Florian Spies, Antonio Madaffari, Annina Salome Vischer, Gregor Fahrni, Raban V. Jeger, Christoph A. Kaiser, Stefan Osswald, Christian Sticherling, Michael Kühne

Open full text 40 citations

Abstract

Background Left bundle branch block ( LBBB ) is common after transcatheter aortic valve implantation ( TAVI ) and is an indicator of subsequent high‐grade atrioventricular block ( HAVB ). No standardized protocol is available to identify LBBB patients at risk for HAVB . The aim of the current study was to evaluate the safety and efficacy of an electrophysiology study tailored strategy in patients with LBBB after TAVI . Methods and Results We prospectively analyzed consecutive patients with LBBB after TAVI . An electrophysiology study was performed to measure the HV ‐interval the day following TAVI . In patients with normal His‐ventricular ( HV )‐interval ≤55 ms, a loop recorder was implanted ( ILR ‐group), whereas pacemaker implantation was performed in patients with prolonged HV ‐interval >55 ms ( PM ‐group). The primary end point was occurrence of HAVB during a follow‐up of 12 months. Secondary end points were symptoms, hospitalizations, adverse events because of device implantation or electrophysiology study, and death. Of 373 patients screened after TAVI , 56 patients (82±6 years, 41% male) with LBBB were included. HAVB occurred in 4 of 41 patients (10%) in the ILR ‐group and in 8 of 15 patients (53%) in the PM ‐group ( P <0.001). We did not identify other predictors for HAVB than the HV interval. The negative predictive value for the cut‐off of HV 55 ms to detect HAVB was 90%. No HAVB ‐related syncope occurred in the 2 groups. Conclusions An electrophysiology study tailored strategy to LBBB after TAVI with a cut‐off of HV >55 ms is a feasible and safe approach to stratify patients with regard to developing HAVB during a follow‐up of 12 months.

Open-access reader

About this research paper

What this paper is about

Background Left bundle branch block ( LBBB ) is common after transcatheter aortic valve implantation ( TAVI ) and is an indicator of subsequent high‐grade atrioventricular block ( HAVB ). No standardized protocol is available to identify LBBB patients at risk for HAVB . The aim of the current study was to evaluate the safety and efficacy of an electrophysiology study tailored strategy in patients with LBBB after TAVI . Methods and Results We prospectively analyzed consecutive patients with LBBB after TAVI . An electrophysiology study was performed to measure the HV ‐interval the day following TAVI . In patients with normal His‐ventricular ( HV )‐interval ≤55 ms, a loop recorder was implanted ( ILR ‐group), whereas pacemaker implantation was performed in patients with prolonged HV ‐interval >55 ms ( PM ‐group). The primary end point was occurrence of HAVB during a follow‐up of 12 months. Secondary end points were symptoms, hospitalizations, adverse events because of device implantation or electrophysiology study, and death. Of 373 patients screened after TAVI , 56 patients (82±6 years, 41% male) with LBBB were included. HAVB occurred in 4 of 41 patients (10%) in the ILR ‐group and in 8 of 15 patients (53%) in the PM ‐group ( P <0.001). We did not identify other predictors for HAVB than the HV interval. The negative predictive value for the cut‐off of HV 55 ms to detect HAVB was 90%. No HAVB ‐related syncope occurred in the 2 groups. Conclusions An electrophysiology study tailored strategy to LBBB after TAVI with a cut‐off of HV >55 ms is a feasible and safe approach to stratify patients with regard to developing HAVB during a follow‐up of 12 months.

Why it matters

OpenAlex reports 40 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Background Left bundle branch block ( LBBB ) is common after transcatheter aortic valve implantation ( TAVI ) and is an indicator of subsequent high‐grade atrioventricular block ( HAVB ). No standardized protocol is available to identify LBBB patients at risk for HAVB . The aim of the current study was to evaluate the safety and efficacy of an electrophysiology study tailored strategy in patients with LBBB after TAVI . Methods and Results We prospectively analyzed consecutive patients with LBBB after TAVI . An electrophysiology study was performed to measure the HV ‐interval the day following TAVI . In patients with normal His‐ventricular ( HV )‐interval ≤55 ms, a loop recorder was implanted ( ILR ‐group), whereas pacemaker implantation was performed in patients with prolonged HV ‐interval >55 ms ( PM ‐group). The primary end point was occurrence of HAVB during a follow‐up of 12 months. Secondary end points were symptoms, hospitalizations, adverse events because of device implantation or electrophysiology study, and death. Of 373 patients screened after TAVI , 56 patients (82±6 years, 41% male) with LBBB were included. HAVB occurred in 4 of 41 patients (10%) in the ILR ‐group and in 8 of 15 patients (53%) in the PM ‐group ( P <0.001). We did not identify other predictors for HAVB than the HV interval. The negative predictive value for the cut‐off of HV 55 ms to detect HAVB was 90%. No HAVB ‐related syncope occurred in the 2 groups. Conclusions An electrophysiology study tailored strategy to LBBB after TAVI with a cut‐off of HV >55 ms is a feasible and safe approach to stratify patients with regard to developing HAVB during a follow‐up of 12 months.

Key concepts: Medicine, Left bundle branch block, Cardiology, Electrophysiology study, Internal medicine, Atrioventricular block, Implantable loop recorder, Bundle branch block

Related papers

Back to paper searchBrowse research topicsOriginal source
Electrophysiology Testing to Stratify Patients With Left Bundle Branch Block After Transcatheter Aortic Valve Implantation — Research Paper | ScholarLens