2018•Iranian journal of medical physicsOpen access

Rabbit internal dosimetry for iodine-131 using GATE Monte Carlo simulation code: a preclinical trial

Shima Yavari, Parham Geramifar, Maryam Fallahpoor, Mehrshad Abbasi

Open full text 0 citations

Abstract

Introduction: One of the main concerns in administration of radiotracers, especially in therapeutic arm, is the amount of delivered dose to the different organs. Individual variations of anatomy, physiology and underlying pathology in the patients lead to alteration of administered activity. In the current study we preclinically applied internal dosimetry using an animal model   Materials and Methods: The SPECT/CT imaging of a rabbit 24 hours after administration of 288μci Iodine-131 was done. Biodistribution of radiotracer was obtained from SPECT, and the CT was used to define attenuation map and the target volume of interest (VOIs). Dosimetry calculations were performed with GATE Monte Carlo code and S-values for beta and gamma radiation of different organs were calculated.   Results: The S-values of thyroid as target organ are 1.09×10-4(mGy/MBq/sec) for beta and 1.05×10- 5 for gamma radiation. And S-values of kidneys, lungs, spine, and heart as critical organs are 1.10×10-5, 1.58×10-5, 7.62×10-6, 6.75×10-6 for beta, respectively and 3.9×10-6, 2.69×10-6, 2.63×10-6, 3.27×10-6 for gamma, respectively Conclusion: The internal dosimetry is applicable clinically. The response to therapy would be increased and the side effect would be minimized if the prescription using patient specific dosimetry is optimized.

About this research paper

What this paper is about

Introduction: One of the main concerns in administration of radiotracers, especially in therapeutic arm, is the amount of delivered dose to the different organs. Individual variations of anatomy, physiology and underlying pathology in the patients lead to alteration of administered activity. In the current study we preclinically applied internal dosimetry using an animal model   Materials and Methods: The SPECT/CT imaging of a rabbit 24 hours after administration of 288μci Iodine-131 was done. Biodistribution of radiotracer was obtained from SPECT, and the CT was used to define attenuation map and the target volume of interest (VOIs). Dosimetry calculations were performed with GATE Monte Carlo code and S-values for beta and gamma radiation of different organs were calculated.   Results: The S-values of thyroid as target organ are 1.09×10-4(mGy/MBq/sec) for beta and 1.05×10- 5 for gamma radiation. And S-values of kidneys, lungs, spine, and heart as critical organs are 1.10×10-5, 1.58×10-5, 7.62×10-6, 6.75×10-6 for beta, respectively and 3.9×10-6, 2.69×10-6, 2.63×10-6, 3.27×10-6 for gamma, respectively Conclusion: The internal dosimetry is applicable clinically. The response to therapy would be increased and the side effect would be minimized if the prescription using patient specific dosimetry is optimized.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Introduction: One of the main concerns in administration of radiotracers, especially in therapeutic arm, is the amount of delivered dose to the different organs. Individual variations of anatomy, physiology and underlying pathology in the patients lead to alteration of administered activity. In the current study we preclinically applied internal dosimetry using an animal model   Materials and Methods: The SPECT/CT imaging of a rabbit 24 hours after administration of 288μci Iodine-131 was done. Biodistribution of radiotracer was obtained from SPECT, and the CT was used to define attenuation map and the target volume of interest (VOIs). Dosimetry calculations were performed with GATE Monte Carlo code and S-values for beta and gamma radiation of different organs were calculated.   Results: The S-values of thyroid as target organ are 1.09×10-4(mGy/MBq/sec) for beta and 1.05×10- 5 for gamma radiation. And S-values of kidneys, lungs, spine, and heart as critical organs are 1.10×10-5, 1.58×10-5, 7.62×10-6, 6.75×10-6 for beta, respectively and 3.9×10-6, 2.69×10-6, 2.63×10-6, 3.27×10-6 for gamma, respectively Conclusion: The internal dosimetry is applicable clinically. The response to therapy would be increased and the side effect would be minimized if the prescription using patient specific dosimetry is optimized.

Key concepts: Dosimetry, Internal dosimetry, Nuclear medicine, Biodistribution, Medicine, Absorbed dose, Monte Carlo method, Medical physics

Related papers

Back to paper searchBrowse research topicsOriginal source
Rabbit internal dosimetry for iodine-131 using GATE Monte Carlo simulation code: a preclinical trial — Research Paper | ScholarLens