2020Mechanics of Advanced Materials and StructuresRequires access

Effects of icing, prestressing and laminate buckling stresses on the design of guyed towers

Sami Alshurafa, Andrew Kenan Rose, Dimos J. Polyzois

Open publisher page 4 citations

Abstract

The article includes a comprehensive review of the design standards and specifications of ice accumulation used to design guyed structures and transmission lines. Both experimental and theoretical results are included. A total of 25 GFRP coupons were tested to failure to obtain material properties. The effects of icing, cable prestressing and the critical buckling stresses due to the extension and shear modes of failure on the design of multi-cell guyed towers are evaluated and discussed. The article evaluates the critical buckling stresses with reference to the percentage of fiber volume fractions and it provides a method to assess and control the design of guyed towers. Moreover, it provides a non-linear finite element model to analyze and set a design limit by predicting the maximum wind load profile that causes failure of the GFRP jointed guyed tower.

About this research paper

What this paper is about

The article includes a comprehensive review of the design standards and specifications of ice accumulation used to design guyed structures and transmission lines. Both experimental and theoretical results are included. A total of 25 GFRP coupons were tested to failure to obtain material properties. The effects of icing, cable prestressing and the critical buckling stresses due to the extension and shear modes of failure on the design of multi-cell guyed towers are evaluated and discussed. The article evaluates the critical buckling stresses with reference to the percentage of fiber volume fractions and it provides a method to assess and control the design of guyed towers. Moreover, it provides a non-linear finite element model to analyze and set a design limit by predicting the maximum wind load profile that causes failure of the GFRP jointed guyed tower.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The article includes a comprehensive review of the design standards and specifications of ice accumulation used to design guyed structures and transmission lines. Both experimental and theoretical results are included. A total of 25 GFRP coupons were tested to failure to obtain material properties. The effects of icing, cable prestressing and the critical buckling stresses due to the extension and shear modes of failure on the design of multi-cell guyed towers are evaluated and discussed. The article evaluates the critical buckling stresses with reference to the percentage of fiber volume fractions and it provides a method to assess and control the design of guyed towers. Moreover, it provides a non-linear finite element model to analyze and set a design limit by predicting the maximum wind load profile that causes failure of the GFRP jointed guyed tower.

Key concepts: Structural engineering, Buckling, Icing, Fibre-reinforced plastic, Finite element method, Engineering, Tower, Geology

Related papers

Back to paper searchBrowse research topicsOriginal source
Effects of icing, prestressing and laminate buckling stresses on the design of guyed towers — Research Paper | ScholarLens