2020The Angle OrthodontistOpen access

Evaluation of an automated superimposition method for computer-aided cephalometrics

Jun‐Ho Moon, Hyewon Hwang, Shin‐Jae Lee

Open full text 15 citations

Abstract

OBJECTIVES: To evaluate a new superimposition method compatible with computer-aided cephalometrics and to compare superimposition error to that of the conventional Sella-Nasion (SN) superimposition method. MATERIALS AND METHODS: A total of 283 lateral cephalometric radiographs were collected and cephalometric landmark identification was performed twice by the same examiner at a 3-month interval. The second tracing was superimposed on the first tracing by both the SN superimposition method and the new, proposed method. The proposed method not only relied on SN landmarks but also minimized the differences between four additional landmarks: Porion, Orbitale, Basion, and Pterygoid. The errors between the landmarks of the duplicate tracings oriented by the two superimposition methods were calculated at Anterior Nasal Spine, Point A, Point B, Pogonion, and Gonion. The paired t-test was used to find any statistical difference in the superimposition errors by the two superimposition methods and to investigate whether there existed clinically significant differences between the two methods. RESULTS: The proposed method demonstrated smaller superimposition errors than did the conventional SN superimposition method. When comparisons between the two superimposition methods were made with a 1-mm error range, there were clinically significant differences between them. CONCLUSIONS: The proposed method that was compatible with computer-aided cephalometrics might be a reliable superimposition method for superimposing serial cephalometric images.

About this research paper

What this paper is about

OBJECTIVES: To evaluate a new superimposition method compatible with computer-aided cephalometrics and to compare superimposition error to that of the conventional Sella-Nasion (SN) superimposition method. MATERIALS AND METHODS: A total of 283 lateral cephalometric radiographs were collected and cephalometric landmark identification was performed twice by the same examiner at a 3-month interval. The second tracing was superimposed on the first tracing by both the SN superimposition method and the new, proposed method. The proposed method not only relied on SN landmarks but also minimized the differences between four additional landmarks: Porion, Orbitale, Basion, and Pterygoid. The errors between the landmarks of the duplicate tracings oriented by the two superimposition methods were calculated at Anterior Nasal Spine, Point A, Point B, Pogonion, and Gonion. The paired t-test was used to find any statistical difference in the superimposition errors by the two superimposition methods and to investigate whether there existed clinically significant differences between the two methods. RESULTS: The proposed method demonstrated smaller superimposition errors than did the conventional SN superimposition method. When comparisons between the two superimposition methods were made with a 1-mm error range, there were clinically significant differences between them. CONCLUSIONS: The proposed method that was compatible with computer-aided cephalometrics might be a reliable superimposition method for superimposing serial cephalometric images.

Why it matters

OpenAlex reports 15 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVES: To evaluate a new superimposition method compatible with computer-aided cephalometrics and to compare superimposition error to that of the conventional Sella-Nasion (SN) superimposition method. MATERIALS AND METHODS: A total of 283 lateral cephalometric radiographs were collected and cephalometric landmark identification was performed twice by the same examiner at a 3-month interval. The second tracing was superimposed on the first tracing by both the SN superimposition method and the new, proposed method. The proposed method not only relied on SN landmarks but also minimized the differences between four additional landmarks: Porion, Orbitale, Basion, and Pterygoid. The errors between the landmarks of the duplicate tracings oriented by the two superimposition methods were calculated at Anterior Nasal Spine, Point A, Point B, Pogonion, and Gonion. The paired t-test was used to find any statistical difference in the superimposition errors by the two superimposition methods and to investigate whether there existed clinically significant differences between the two methods. RESULTS: The proposed method demonstrated smaller superimposition errors than did the conventional SN superimposition method. When comparisons between the two superimposition methods were made with a 1-mm error range, there were clinically significant differences between them. CONCLUSIONS: The proposed method that was compatible with computer-aided cephalometrics might be a reliable superimposition method for superimposing serial cephalometric images.

Key concepts: Superimposition, Engineering drawing, Computer science, Computer-aided, Orthodontics, Dentistry, Computer graphics (images), Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Evaluation of an automated superimposition method for computer-aided cephalometrics — Research Paper | ScholarLens