2018Materiale PlasticeOpen access

Studies of Humic Acid Removal from Aqueous Systems by Using Polymeric Membrane Ultrafiltration Process

Laureniu Tataru, Valentin Nedeff, Narcis Bârsan, Emilian Moșneguțu, Mirela Panainte Lehadus, Ion Sandu, Dana Chițimuș

Open full text 8 citations

Abstract

This paper proposes to investigate in detail the behavior of polymeric membranes ultrafiltration process uses in the retention of humic acid from aqueous systems. Nowadays, the aqueous systems (contaminated water and/or wastewater) resulting from various domestic and industrial activities contain many contaminants, some of them increasingly dangerous to the environment. Laboratory testing of membranes in the ultrafiltration process as well as their experimentation with different chemical compounds is essential because it is important to know how they can be eliminated before they cause a negative impact. Testing of polymeric membranes consists in carrying out the process of ultrafiltration of aqueous systems containing humic acid over a set time, following the variation in time of the volume of permeate obtained as well as the influence of process parameters. Following the investigation of the ultrafiltration process of the water through the polymeric membrane, it was found that the formation of the humic acid layer on the surface of the membrane that favors fouling is delayed, after many hours of operation, due to both the internal fiber structure which offers advantages to this type of membranes as well as high efficiency of humic acid retention. Experimental results showed that the humic acid retention rate increased by up to 37% as a result of the double decrease of the conductivity value in the permeate samples from about 600 mS/cm to 373 mS/cm and the temperature being continuously increasing, from 22.5 at 25oC over 5 h influenced the entire ultrafiltration process. The full process approach as well as the expression and interpretation of the results will be detailed in this paper.

Open-access reader

About this research paper

What this paper is about

This paper proposes to investigate in detail the behavior of polymeric membranes ultrafiltration process uses in the retention of humic acid from aqueous systems. Nowadays, the aqueous systems (contaminated water and/or wastewater) resulting from various domestic and industrial activities contain many contaminants, some of them increasingly dangerous to the environment. Laboratory testing of membranes in the ultrafiltration process as well as their experimentation with different chemical compounds is essential because it is important to know how they can be eliminated before they cause a negative impact. Testing of polymeric membranes consists in carrying out the process of ultrafiltration of aqueous systems containing humic acid over a set time, following the variation in time of the volume of permeate obtained as well as the influence of process parameters. Following the investigation of the ultrafiltration process of the water through the polymeric membrane, it was found that the formation of the humic acid layer on the surface of the membrane that favors fouling is delayed, after many hours of operation, due to both the internal fiber structure which offers advantages to this type of membranes as well as high efficiency of humic acid retention. Experimental results showed that the humic acid retention rate increased by up to 37% as a result of the double decrease of the conductivity value in the permeate samples from about 600 mS/cm to 373 mS/cm and the temperature being continuously increasing, from 22.5 at 25oC over 5 h influenced the entire ultrafiltration process. The full process approach as well as the expression and interpretation of the results will be detailed in this paper.

Why it matters

OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This paper proposes to investigate in detail the behavior of polymeric membranes ultrafiltration process uses in the retention of humic acid from aqueous systems. Nowadays, the aqueous systems (contaminated water and/or wastewater) resulting from various domestic and industrial activities contain many contaminants, some of them increasingly dangerous to the environment. Laboratory testing of membranes in the ultrafiltration process as well as their experimentation with different chemical compounds is essential because it is important to know how they can be eliminated before they cause a negative impact. Testing of polymeric membranes consists in carrying out the process of ultrafiltration of aqueous systems containing humic acid over a set time, following the variation in time of the volume of permeate obtained as well as the influence of process parameters. Following the investigation of the ultrafiltration process of the water through the polymeric membrane, it was found that the formation of the humic acid layer on the surface of the membrane that favors fouling is delayed, after many hours of operation, due to both the internal fiber structure which offers advantages to this type of membranes as well as high efficiency of humic acid retention. Experimental results showed that the humic acid retention rate increased by up to 37% as a result of the double decrease of the conductivity value in the permeate samples from about 600 mS/cm to 373 mS/cm and the temperature being continuously increasing, from 22.5 at 25oC over 5 h influenced the entire ultrafiltration process. The full process approach as well as the expression and interpretation of the results will be detailed in this paper.

Key concepts: Humic acid, Ultrafiltration (renal), Membrane, Aqueous solution, Chemistry, Permeation, Membrane fouling, Fouling

Related papers

Back to paper searchBrowse research topicsOriginal source
Studies of Humic Acid Removal from Aqueous Systems by Using Polymeric Membrane Ultrafiltration Process — Research Paper | ScholarLens