2020Plasma Sources Science and TechnologyOpen access

Experimental studies of the difference between plasma potentials measured by Langmuir probes and emissive probes in presheaths

Peixuan Li, N. Hershkowitz, Eugene Wackerbarth, Greg Severn

Open full text 14 citations

Abstract

Abstract The plasma potential measured by cylindrical and planar Langmuir probes has been shown to differ from the plasma potential measured by emissive probes in the neighborhood of the presheath near a negatively biased electrode immersed in a weakly collisional low temperature argon plasma. There are two principal results demonstrated in this paper. First, while it is well known that Langmuir probes cannot reliably measure plasma potentials inside of sheaths, results presented here demonstrate that the problem persists in presheaths, the quasineutral plasma bordering sheaths. It is known that emissive probes analyzed in the limit of zero emission accurately measure the plasma potential in the sheath. It is now clear that they are the only known electrostatic probe technique able to measure the plasma potential accurately throughout the presheath. Second, it is shown that the difference between potential measurements made by Langmuir probes and emissive probes in the body of the plasma, farther than a presheath distance from the boundary, is not proportional to T e , as has been previously claimed.

Open-access reader

About this research paper

What this paper is about

Abstract The plasma potential measured by cylindrical and planar Langmuir probes has been shown to differ from the plasma potential measured by emissive probes in the neighborhood of the presheath near a negatively biased electrode immersed in a weakly collisional low temperature argon plasma. There are two principal results demonstrated in this paper. First, while it is well known that Langmuir probes cannot reliably measure plasma potentials inside of sheaths, results presented here demonstrate that the problem persists in presheaths, the quasineutral plasma bordering sheaths. It is known that emissive probes analyzed in the limit of zero emission accurately measure the plasma potential in the sheath. It is now clear that they are the only known electrostatic probe technique able to measure the plasma potential accurately throughout the presheath. Second, it is shown that the difference between potential measurements made by Langmuir probes and emissive probes in the body of the plasma, farther than a presheath distance from the boundary, is not proportional to T e , as has been previously claimed.

Why it matters

OpenAlex reports 14 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract The plasma potential measured by cylindrical and planar Langmuir probes has been shown to differ from the plasma potential measured by emissive probes in the neighborhood of the presheath near a negatively biased electrode immersed in a weakly collisional low temperature argon plasma. There are two principal results demonstrated in this paper. First, while it is well known that Langmuir probes cannot reliably measure plasma potentials inside of sheaths, results presented here demonstrate that the problem persists in presheaths, the quasineutral plasma bordering sheaths. It is known that emissive probes analyzed in the limit of zero emission accurately measure the plasma potential in the sheath. It is now clear that they are the only known electrostatic probe technique able to measure the plasma potential accurately throughout the presheath. Second, it is shown that the difference between potential measurements made by Langmuir probes and emissive probes in the body of the plasma, farther than a presheath distance from the boundary, is not proportional to T e , as has been previously claimed.

Key concepts: Langmuir probe, Plasma, Plasma diagnostics, Argon, Atomic physics, Chemistry, Plasma parameters, Debye sheath

Related papers

Back to paper searchBrowse research topicsOriginal source
Experimental studies of the difference between plasma potentials measured by Langmuir probes and emissive probes in presheaths — Research Paper | ScholarLens