2020Catheterization and Cardiovascular InterventionsRequires access

Percutaneous nitinol‐based vascular closure device for large bore arterial access hemostasis: Results of a prospective multicenter study

Israel M. Barbash, Ran Kornowski, Anat Berkovitch, Abid Assali, Magdalena Erlebach, Victor Guetta, Hana Vaknin‐Assa, Rüediger Lange, Amit Segev, Hendrik Ruge

Open publisher page 6 citations

Abstract

BACKGROUND: Vascular complications during transcatheter aortic valve replacement (TAVR) still pose a significant concern regarding procedural safety. Designated closure devices for large-bore vascular access are needed. METHODS: Patients undergoing TAVR were prospectively enrolled into the study. The InSeal vascular closure device (VCD) achieves hemostasis by utilizing a crescent-shaped nitinol scaffold covered by a biodegradable membrane, which is delivered at the arterial puncture site. The coprimary endpoints were predefined as hemostasis within 15 min following vessel access site closure and after activated clotting time falls below 200 s and the rate of related major vascular adverse events in first month. RESULTS: A total of 50 patients were prospectively enrolled into the study, with an average age of 80.8 ± 7.4 years and 62% males. Hemostasis with the Inseal VCD was achieved in 94% of the patients with average time-to-hemostasis of 51 ± 97 s. The rates of in-hospital vascular complications were 12% mostly driven by minor vascular complications (10%). Femoral artery stents were used in three patients due to failed hemostasis. CONCLUSIONS: Initial clinical experience indicates that a novel, nitinol-based, large-bore vascular closure device is safe and effective in achieving hemostasis after TAVR.

About this research paper

What this paper is about

BACKGROUND: Vascular complications during transcatheter aortic valve replacement (TAVR) still pose a significant concern regarding procedural safety. Designated closure devices for large-bore vascular access are needed. METHODS: Patients undergoing TAVR were prospectively enrolled into the study. The InSeal vascular closure device (VCD) achieves hemostasis by utilizing a crescent-shaped nitinol scaffold covered by a biodegradable membrane, which is delivered at the arterial puncture site. The coprimary endpoints were predefined as hemostasis within 15 min following vessel access site closure and after activated clotting time falls below 200 s and the rate of related major vascular adverse events in first month. RESULTS: A total of 50 patients were prospectively enrolled into the study, with an average age of 80.8 ± 7.4 years and 62% males. Hemostasis with the Inseal VCD was achieved in 94% of the patients with average time-to-hemostasis of 51 ± 97 s. The rates of in-hospital vascular complications were 12% mostly driven by minor vascular complications (10%). Femoral artery stents were used in three patients due to failed hemostasis. CONCLUSIONS: Initial clinical experience indicates that a novel, nitinol-based, large-bore vascular closure device is safe and effective in achieving hemostasis after TAVR.

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Vascular complications during transcatheter aortic valve replacement (TAVR) still pose a significant concern regarding procedural safety. Designated closure devices for large-bore vascular access are needed. METHODS: Patients undergoing TAVR were prospectively enrolled into the study. The InSeal vascular closure device (VCD) achieves hemostasis by utilizing a crescent-shaped nitinol scaffold covered by a biodegradable membrane, which is delivered at the arterial puncture site. The coprimary endpoints were predefined as hemostasis within 15 min following vessel access site closure and after activated clotting time falls below 200 s and the rate of related major vascular adverse events in first month. RESULTS: A total of 50 patients were prospectively enrolled into the study, with an average age of 80.8 ± 7.4 years and 62% males. Hemostasis with the Inseal VCD was achieved in 94% of the patients with average time-to-hemostasis of 51 ± 97 s. The rates of in-hospital vascular complications were 12% mostly driven by minor vascular complications (10%). Femoral artery stents were used in three patients due to failed hemostasis. CONCLUSIONS: Initial clinical experience indicates that a novel, nitinol-based, large-bore vascular closure device is safe and effective in achieving hemostasis after TAVR.

Key concepts: Medicine, Percutaneous, Vascular closure device, Hemostasis, Vascular access, Multicenter study, Surgery, Cardiology