2019Scientific ReportsOpen access

Eye lens radiation exposure in paediatric interventional treatment of retinoblastoma

A. Obesso, Luis Alejo, C. Huerga, F. Sánchez-Muñoz, E. Corredoira, A. Prieto, R. Frutos, Belén Sánchez Marín, Gonzalo Garzón, Jesús Peralta, Carlos Ubeda, E. Guibelalde

Open full text 11 citations

Abstract

Abstract Retinoblastoma represents 3% of cancers in children under fifteen years of age. The standard paediatric treatment for saving the affected eye is supraselective intra-arterial chemotherapy performed in interventional rooms. In order to address the radiation toxicity due to the angiography, the aim of this study was to determine the typical dose value corresponding to the procedure, estimate the paediatric patients’ eye lens dose and study the relationship between dose indicators and dose to the lens. An automatic dose management software was installed in two interventional rooms to obtain the distribution of the dose indicators kerma-area product and reference-point air kerma, getting a typical value 16 Gy·cm2 and 130 mGy, respectively (n = 35). The eye lens dose estimates were obtained with photoluminescent dosimeters placed on the patient’s eyelids. In the left eye, the entrance surface air kerma was 44.23 ± 2.66 mGy, and 12.72 ± 0.89 mGy in the right eye (n = 10). There was a positive correlation between dose to the lens per procedure and dose indicators, with R2 > 0.65 for both eyes. Based on this information, the threshold for the onset of radiation-induce cataracts (500 mGy) will be exceeded if the treatment is performed for more than 8 sessions.

Open-access reader

About this research paper

What this paper is about

Abstract Retinoblastoma represents 3% of cancers in children under fifteen years of age. The standard paediatric treatment for saving the affected eye is supraselective intra-arterial chemotherapy performed in interventional rooms. In order to address the radiation toxicity due to the angiography, the aim of this study was to determine the typical dose value corresponding to the procedure, estimate the paediatric patients’ eye lens dose and study the relationship between dose indicators and dose to the lens. An automatic dose management software was installed in two interventional rooms to obtain the distribution of the dose indicators kerma-area product and reference-point air kerma, getting a typical value 16 Gy·cm2 and 130 mGy, respectively (n = 35). The eye lens dose estimates were obtained with photoluminescent dosimeters placed on the patient’s eyelids. In the left eye, the entrance surface air kerma was 44.23 ± 2.66 mGy, and 12.72 ± 0.89 mGy in the right eye (n = 10). There was a positive correlation between dose to the lens per procedure and dose indicators, with R2 > 0.65 for both eyes. Based on this information, the threshold for the onset of radiation-induce cataracts (500 mGy) will be exceeded if the treatment is performed for more than 8 sessions.

Why it matters

OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract Retinoblastoma represents 3% of cancers in children under fifteen years of age. The standard paediatric treatment for saving the affected eye is supraselective intra-arterial chemotherapy performed in interventional rooms. In order to address the radiation toxicity due to the angiography, the aim of this study was to determine the typical dose value corresponding to the procedure, estimate the paediatric patients’ eye lens dose and study the relationship between dose indicators and dose to the lens. An automatic dose management software was installed in two interventional rooms to obtain the distribution of the dose indicators kerma-area product and reference-point air kerma, getting a typical value 16 Gy·cm2 and 130 mGy, respectively (n = 35). The eye lens dose estimates were obtained with photoluminescent dosimeters placed on the patient’s eyelids. In the left eye, the entrance surface air kerma was 44.23 ± 2.66 mGy, and 12.72 ± 0.89 mGy in the right eye (n = 10). There was a positive correlation between dose to the lens per procedure and dose indicators, with R2 > 0.65 for both eyes. Based on this information, the threshold for the onset of radiation-induce cataracts (500 mGy) will be exceeded if the treatment is performed for more than 8 sessions.

Key concepts: Kerma, Eye lens, Retinoblastoma, Dosimeter, Medicine, Cataracts, Lens (geology), Nuclear medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Eye lens radiation exposure in paediatric interventional treatment of retinoblastoma — Research Paper | ScholarLens