2019Fluid DynamicsRequires access

Effects of Angle of Attack and Bluntness on Heating Rate Distribution of Blunt Models at Hypersonic Speeds

M. Saiprakash, C. Senthilkumar, Ghanta Sunil, Singh Prakash Rampratap, Vigneshwaran Shanmugam, G. Balu

Open publisher page 7 citations

Abstract

The effects of nose radius on stagnation and surface heat transfer rate along the surface are addressed in this research paper. Experiments are carried out in hypersonic shock tunnel, at hypersonic Mach number of 6.56 for 11.38° apex angle blunt cone with nose radius of 0.2 R , base radius of R . Similarly, experiments are carried out at Mach 7.32 for 13.87° apex angle blunt cone models with nose radius of 0.18 R ′, base radius of R ′. Test is performed at stagnation enthalpy of 1.4 and 2 MJ/kg with effective test time of 3.5 ms. Convective heat transfer measurements have been carried out on the test model at two different angles of attack, namely 0° and 5° with angle of rotation of 0°, 90°,180° with platinum thin film sensors. ANSYS-Fluent used to simulate the flow over the blunt models at different Mach numbers. The measured shock standoff distance from Schlieren visualization images compared with theory and computational fluid dynamic study for both configurations. The measured stagnation heating value is compared with theoretical value estimated using Fay-Riddell expression and numerical simulation. The measured heat transfer rate is higher for configuration 1 than configuration 2. The increases in heat transfer rate is due higher density ratio across the shock wave and the reduced shock layer thickness. The measured shock layer thickness is 2.06 mm for Mach 6.56 and 3.45 mm for Mach 7.32. The heat transfer rate is higher for Mach 6.56 as compared to Mach 7.32.

About this research paper

What this paper is about

The effects of nose radius on stagnation and surface heat transfer rate along the surface are addressed in this research paper. Experiments are carried out in hypersonic shock tunnel, at hypersonic Mach number of 6.56 for 11.38° apex angle blunt cone with nose radius of 0.2 R , base radius of R . Similarly, experiments are carried out at Mach 7.32 for 13.87° apex angle blunt cone models with nose radius of 0.18 R ′, base radius of R ′. Test is performed at stagnation enthalpy of 1.4 and 2 MJ/kg with effective test time of 3.5 ms. Convective heat transfer measurements have been carried out on the test model at two different angles of attack, namely 0° and 5° with angle of rotation of 0°, 90°,180° with platinum thin film sensors. ANSYS-Fluent used to simulate the flow over the blunt models at different Mach numbers. The measured shock standoff distance from Schlieren visualization images compared with theory and computational fluid dynamic study for both configurations. The measured stagnation heating value is compared with theoretical value estimated using Fay-Riddell expression and numerical simulation. The measured heat transfer rate is higher for configuration 1 than configuration 2. The increases in heat transfer rate is due higher density ratio across the shock wave and the reduced shock layer thickness. The measured shock layer thickness is 2.06 mm for Mach 6.56 and 3.45 mm for Mach 7.32. The heat transfer rate is higher for Mach 6.56 as compared to Mach 7.32.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The effects of nose radius on stagnation and surface heat transfer rate along the surface are addressed in this research paper. Experiments are carried out in hypersonic shock tunnel, at hypersonic Mach number of 6.56 for 11.38° apex angle blunt cone with nose radius of 0.2 R , base radius of R . Similarly, experiments are carried out at Mach 7.32 for 13.87° apex angle blunt cone models with nose radius of 0.18 R ′, base radius of R ′. Test is performed at stagnation enthalpy of 1.4 and 2 MJ/kg with effective test time of 3.5 ms. Convective heat transfer measurements have been carried out on the test model at two different angles of attack, namely 0° and 5° with angle of rotation of 0°, 90°,180° with platinum thin film sensors. ANSYS-Fluent used to simulate the flow over the blunt models at different Mach numbers. The measured shock standoff distance from Schlieren visualization images compared with theory and computational fluid dynamic study for both configurations. The measured stagnation heating value is compared with theoretical value estimated using Fay-Riddell expression and numerical simulation. The measured heat transfer rate is higher for configuration 1 than configuration 2. The increases in heat transfer rate is due higher density ratio across the shock wave and the reduced shock layer thickness. The measured shock layer thickness is 2.06 mm for Mach 6.56 and 3.45 mm for Mach 7.32. The heat transfer rate is higher for Mach 6.56 as compared to Mach 7.32.

Key concepts: Hypersonic speed, Angle of attack, Blunt, Mechanics, Materials science, Distribution (mathematics), Aerospace engineering, Hypersonic flow

Related papers

Back to paper searchBrowse research topicsOriginal source
Effects of Angle of Attack and Bluntness on Heating Rate Distribution of Blunt Models at Hypersonic Speeds — Research Paper | ScholarLens