Thermodynamic Analysis of a CO2 Refrigeration Cycle with Integrated Mechanical Subcooling
Laura Nebot‐Andrés, Daniel Calleja-Anta, Daniel Sánchez, Ramón Cabello, Rodrigo Llopis
Abstract
Open-access reader
Laura Nebot‐Andrés, Daniel Calleja-Anta, Daniel Sánchez, Ramón Cabello, Rodrigo Llopis
Abstract
Open-access reader
Different alternatives are being studied nowadays in order to enhance the behavior of transcritical CO2 refrigeration plants. Among the most studied options, subcooling is one of the most analyzed methods in the last years, increasing cooling capacity and Coefficient Of Performance (COP), especially at high hot sink temperatures. A new cycle, called integrated mechanical subcooling cycle, has been developed, as a total-CO2 solution, to provide the subcooling in CO2 transcritical refrigeration cycles. It corresponds to a promising solution from the point of view of energy efficiency. The purpose of this work is to present, for the first time, thermodynamic analysis of a CO2 refrigeration cycle with integrated mechanical subcooling cycle from first and second law approaches. Using simplified models of the components, the optimum operating conditions, optimum gas-cooler pressure, and subcooling degree are determined in order to obtain the maximum COP. The main energy parameters of the system were analyzed for different evaporation levels and heat rejection temperatures. The exergy destruction was analyzed for each component, identifying the elements of the system that introduce more irreversibilities. It has been concluded that the new cycle could offer COP improvements from 11.7% to 15.9% in relation to single-stage cycles with internal heat exchanger (IHX) at 35 °C ambient temperature.
OpenAlex reports 20 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Different alternatives are being studied nowadays in order to enhance the behavior of transcritical CO2 refrigeration plants. Among the most studied options, subcooling is one of the most analyzed methods in the last years, increasing cooling capacity and Coefficient Of Performance (COP), especially at high hot sink temperatures. A new cycle, called integrated mechanical subcooling cycle, has been developed, as a total-CO2 solution, to provide the subcooling in CO2 transcritical refrigeration cycles. It corresponds to a promising solution from the point of view of energy efficiency. The purpose of this work is to present, for the first time, thermodynamic analysis of a CO2 refrigeration cycle with integrated mechanical subcooling cycle from first and second law approaches. Using simplified models of the components, the optimum operating conditions, optimum gas-cooler pressure, and subcooling degree are determined in order to obtain the maximum COP. The main energy parameters of the system were analyzed for different evaporation levels and heat rejection temperatures. The exergy destruction was analyzed for each component, identifying the elements of the system that introduce more irreversibilities. It has been concluded that the new cycle could offer COP improvements from 11.7% to 15.9% in relation to single-stage cycles with internal heat exchanger (IHX) at 35 °C ambient temperature.
Key concepts: Subcooling, Transcritical cycle, Refrigeration, Coefficient of performance, Thermodynamics, Exergy, Economizer, Heat exchanger