2019Chinese Journal of TraumatologyOpen access

Percutaneous suture technique with ProGlide to manage vascular access pseudoaneurysm after percutaneous coronary intervention procedure: A case report

Wei Liu, Chao Liu, Shaoying Lu

Open full text 10 citations

Abstract

Iatrogenic femoral artery pseudoaneurysm is a common complication of the endovascular procedures. Manual compression and thrombin injection are the conventional techniques to occlude the pseudoaneurysms. However, there are still some failed cases that applied these treatment options. The aim of the study is to seek a potential and alternative method with ProGlide system to close the pseudoaneurysm. During April 2018 to February 2019, 2 patients with iatrogenic pseudoaneurysm of the superficial femoral were treated with the suture-base closure device--ProGlide. After punctured the pseudoaneurysm and placed a 6-F sheath, the guide wire was placed in the right femoral artery via the access of the pseudoaneurysm neck. Then the pseudoaneurysm neck was sutured by ProGlide to occlude the blood supply to the pseudoaneurysm. These 2 patients were cured with no complications and complaints, which revealed that percutaneous suture technique with ProGlide at the neck level of pseudoaneurysm provides a novel method for the management of vascular access pseudoaneurysm, especially in those with a wide and short neck.

Open-access reader

About this research paper

What this paper is about

Iatrogenic femoral artery pseudoaneurysm is a common complication of the endovascular procedures. Manual compression and thrombin injection are the conventional techniques to occlude the pseudoaneurysms. However, there are still some failed cases that applied these treatment options. The aim of the study is to seek a potential and alternative method with ProGlide system to close the pseudoaneurysm. During April 2018 to February 2019, 2 patients with iatrogenic pseudoaneurysm of the superficial femoral were treated with the suture-base closure device--ProGlide. After punctured the pseudoaneurysm and placed a 6-F sheath, the guide wire was placed in the right femoral artery via the access of the pseudoaneurysm neck. Then the pseudoaneurysm neck was sutured by ProGlide to occlude the blood supply to the pseudoaneurysm. These 2 patients were cured with no complications and complaints, which revealed that percutaneous suture technique with ProGlide at the neck level of pseudoaneurysm provides a novel method for the management of vascular access pseudoaneurysm, especially in those with a wide and short neck.

Why it matters

OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Iatrogenic femoral artery pseudoaneurysm is a common complication of the endovascular procedures. Manual compression and thrombin injection are the conventional techniques to occlude the pseudoaneurysms. However, there are still some failed cases that applied these treatment options. The aim of the study is to seek a potential and alternative method with ProGlide system to close the pseudoaneurysm. During April 2018 to February 2019, 2 patients with iatrogenic pseudoaneurysm of the superficial femoral were treated with the suture-base closure device--ProGlide. After punctured the pseudoaneurysm and placed a 6-F sheath, the guide wire was placed in the right femoral artery via the access of the pseudoaneurysm neck. Then the pseudoaneurysm neck was sutured by ProGlide to occlude the blood supply to the pseudoaneurysm. These 2 patients were cured with no complications and complaints, which revealed that percutaneous suture technique with ProGlide at the neck level of pseudoaneurysm provides a novel method for the management of vascular access pseudoaneurysm, especially in those with a wide and short neck.

Key concepts: Pseudoaneurysm, Medicine, Percutaneous, Fibrous joint, Vascular closure device, Femoral artery, Surgery, Radiology

Related papers

Back to paper searchBrowse research topicsOriginal source
Percutaneous suture technique with ProGlide to manage vascular access pseudoaneurysm after percutaneous coronary intervention procedure: A case report — Research Paper | ScholarLens