Amberlite XAD resin solid phase extraction coupled on-line to flow injection systems using 4-(2-pyridylazo resorcinol) as reagent for preconcentration and determination of zinc in water
Jintana Klamtet, Wilawan Boonaim, Orapan Songsang
Abstract
Jintana Klamtet, Wilawan Boonaim, Orapan Songsang
Abstract
A determination of Zn(II) in water based on solid phase extraction coupled on-line to a flow injection analysis manifold is described. The method employs on-line preconcentration of Zn(II) onto a 1.3 cm × 1.0 mm (length × i.d.) column packed with Amberlite XAD-4 or Amberlite XAD-7 resins. The Zn(II) are subsequently eluted from the resin into a flowing system by 0.02 and 0.01 M HCl solution for Amberlite XAD-4 and XAD-7, respectively. Then the eluted analytes were quantified spectrophotometrically at 492 nm as the products of reaction with 4-(2-pyridylazo) resorcinol in buffer pH 11. The proposed methods have a linear calibration in range of 0.05-0.20, 0.20-0.80 mg L-1 for Amberlite XAD-4 and 0.05-0.40, 0.60-1.40 mg L-1 for Amberlite XAD-7, respectively. Detection limit of 0.016 and 0.013 mg L-1 and sample throughput of 30 and 26 h-1 were obtained for Amberlite XAD-4 and XAD-7, respectively. The procedure was successfully applied to the determination of Zn(II) in water sample, and the results were statistically compared with flame atomic absorption spectrometry. Keywords: Flow injection analysis, Zinc, 4-(2-pyridylazo resorcinol), Preconcentration
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A determination of Zn(II) in water based on solid phase extraction coupled on-line to a flow injection analysis manifold is described. The method employs on-line preconcentration of Zn(II) onto a 1.3 cm × 1.0 mm (length × i.d.) column packed with Amberlite XAD-4 or Amberlite XAD-7 resins. The Zn(II) are subsequently eluted from the resin into a flowing system by 0.02 and 0.01 M HCl solution for Amberlite XAD-4 and XAD-7, respectively. Then the eluted analytes were quantified spectrophotometrically at 492 nm as the products of reaction with 4-(2-pyridylazo) resorcinol in buffer pH 11. The proposed methods have a linear calibration in range of 0.05-0.20, 0.20-0.80 mg L-1 for Amberlite XAD-4 and 0.05-0.40, 0.60-1.40 mg L-1 for Amberlite XAD-7, respectively. Detection limit of 0.016 and 0.013 mg L-1 and sample throughput of 30 and 26 h-1 were obtained for Amberlite XAD-4 and XAD-7, respectively. The procedure was successfully applied to the determination of Zn(II) in water sample, and the results were statistically compared with flame atomic absorption spectrometry. Keywords: Flow injection analysis, Zinc, 4-(2-pyridylazo resorcinol), Preconcentration
Key concepts: Amberlite, Resorcinol, Chemistry, Solid phase extraction, Elution, Chromatography, Extraction (chemistry), Detection limit